20
ARPEX 8704 en
Operating instructions 01/2019
6.6.1
Fitting
During fitting the following procedure must be observed:
•
Degrease the hub bore and shaft.
Hub bore and shaft must be absolutely clean and free of grease.
Observe the manufacturer’s instructions for handling the solvent.
•
Slightly loosen the tensioning bolts and pull the clamping ring off the hub slightly so that the clamping
ring sits loosely on it.
•
Push the hub onto the shaft.
•
Tighten the tensioning bolts evenly one after the other, going round several times until the clamping ring
lies evenly against the flange of the clamping or slip hub. The clamp connection is able to function when
the torque for tensioning bolts (quality 10.9) specified in table 5, "Tightening torques for connecting and
tensioning bolts" in item 6.8.1 has been reached and the clamping ring thus lies up against the hub
flange.
Failure to observe these instructions may impair the function of the clamping and/or
slip hub.
3
1
2
Fig. 13:
Demounting with highpressure pump
1
Forcing-off bolt ISO 4017
2
G1/4"
3
High-pressure pump
Summary of Contents for ARPEX ARC-10