45
5. Drill a ¼” hole through the pull handle. The
center of the hole should be ¼” above the
handle arch and centered.
6. Install the valve, spring and handle
assembly onto the modified spout.
7. Install the freezer door with spout assembly
onto the freezer.
8. Insert the Flow Rate Controller inside the
spring of the spout. Ensure the encased end
of the Controller is toward the back of the
spout.
9. Install the switch over the threaded end of
the modified spout and install the spout cap
to secure the assembly.
10. Insert the bolt through the magnetic actuator
and then through the hole in the handle.
Use the nut to secure the assembly. The
magnetic actuator should be in front of the
handle.
11. Remove the cap on the 9-Tube Assembly
and insert it into the syrup port under the
freezer head. Turn the manifold off-center
to lock the connection.
12. When the draw switch is pulled forward, the
magnet comes close to the switch and
activates it.
26403
26411
26406
NUT
BOLT
MAGNETIC
ACTUATOR
26407
26413
Summary of Contents for JBT 80FCB-2B
Page 4: ...3 PAGE INTENTIONALLY LEFT BLANK...
Page 7: ...6 PAGE INTENTIONALLY LEFT BLANK...
Page 9: ...8 General System Overview Figure 1...
Page 15: ...14 Syrup Pump and Related Parts Figure 4 6 7 5 8 9 10 4 3 26004 1 1D 1C 1A 1E 1B 2 2B 2A 2D 2C...
Page 19: ...18 Cabinet Electronics Figure 6...
Page 22: ...21 2B 3B Jumbo Touch Panel Electronics See Figure 7...
Page 23: ...22 2B 3B Jumbo Touch Panel Electronics Figure 7...
Page 26: ...25 4B Jumbo Touch Panel Electronics See Figure 8...
Page 27: ...26 4B Jumbo Touch Panel Electronics Figure 8...
Page 44: ...43 PAGE INTENTIONALLY LEFT BLANK...