background image

Revision Date

20131125

Document numbeR

notice 

The manufacturer will accept no responsability for any electrical 

damage resulting from improper installation of this product, be that either 

damage to the vehicle itself or to the installed device. This device must be in-

stalled by a certified technician. Please review the Installation Guide carefully 

before beginning any work. 

beFoRe instaLLation

1- Connect module to computer

2- Login to Weblink account

3- Flash firmware to module (module is not preloaded with firmware)

4- Use accessories accordingly (accessories are sold separately)

instaLL guiDe

OEM-CH(RS)-CH5-[FLRSCH5]-EN

haRDwaRe

FLRSCH5

FiRmwaRe

OEM-CH(RS)-CH5-[FLRSCH5]

www.flashlogic.com

Automotive Data Solutions Inc. © 2013

accessoRies

FLPROG (REQUIRED)

 

 

 

13103

Summary of Contents for FLRSCH5

Page 1: ...y a certified technician Please review the Installation Guide carefully before beginning any work BEFORE INSTALLATION 1 Connect module to computer 2 Login to Weblink account 3 Flash firmware to module...

Page 2: ...06 07 1 or 3 Durango AT 07 10 2 Magnum AT 05 07 1 or 3 Nitro AT 07 11 2 Ram 1500 AT 07 08 2 Ram 2500 AT 07 09 2 Ram 3500 AT 07 09 2 Ram 3500 chassis cab AT 07 09 2 Ram 4500 chassis cab AT 08 10 2 Ram...

Page 3: ...HOOD SWITCH AND CABLE WARNING STICKER 10 PIN CONNECTOR 12 PIN CONNECTOR MODULE LED 2 LED 1 PROGRAMMING BUTTON WEBLINK CABLE required accessory sold separately WEBLINK CABLE COMPUTER USB PORT 4 PIN BLA...

Page 4: ...ontrol C1 Black 5 pin 2 Violet Brown MUX Ignition switch Starter C1 Black 5 pin 4 Pink DkGreen Ignition switch Parking Light White Purple Driver kick panel Driver Door Pin Purple Driver kick panel Hoo...

Page 5: ...REEN WIRE FROM THE BLUE CONNECTOR AND RE INSERT IT IN PIN 6 AS SHOWN SEE DETAILED INSTRUCTIONS ON THE NEXT PAGE CONNECT THE WHITE GREEN WIRE TO THE PINK WIRE AND CONNECT THE WHITE RED WIRE TO THE RED...

Page 6: ...RE STRIPPER DO NOT CUT THE WIRES IN THE PROCESS STEP 2 CONNECT AND SOLDER THE WHITE RED WIRE TO THE RED WIRE CONNECT AND SOLDER THE WHITE GREEN WIRE TO THE PINK WIRE STEP 2 USING A UTILITY KNIFE LIFT...

Page 7: ...panel Hood Status Purple LtBlue Switch DODGE Avenger 08 13 Mux Starter Parking Light White Purple Driver kick panel Driver Door Pin Purple Driver kick panel Hood Status Caliber 07 12 Mux Starter Park...

Page 8: ...tus Ram 4500 08 10 Mux Starter Parking Light White Green MUX Switch Driver Door Pin Purple Driver kick panel Hood Status Purple LtBlue Switch Ram 5500 08 10 Mux Starter Parking Light White Green MUX S...

Page 9: ...ing Light White Purple White Orange Passenger kick pad Driver Door Pin Purple Driver kick panel Hood Status Purple LtBlue Switch RAM 4500 10 Mux Starter Parking Light White Green MUX Switch Driver Doo...

Page 10: ...IGNITION SWITCH MODULE 11 GRAY GREEN HORN OUTPUT VEHICLE DRIVER DOOR PIN PARKING LIGHT MUX PARKING LIGHT PARKING LIGHT 12V CONNECT IF VEHICLE IS EQUIPPED WITH PARKING LIGHT MUX CONNECT IF VEHICLE IS...

Page 11: ...ntrol C1 Black 5 pin 2 Violet Brown MUX Ignition switch Starter C1 Black 5 pin 4 Pink DkGreen Ignition switch Parking Light White Purple Driver kick panel Driver Door Pin Purple Driver kick panel Hood...

Page 12: ...RN OPTIONAL CONTROL MUX 02 STARTER 04 WHITE YELLOW CONTROL MUX OUTPUT PURPLE STARTER OUTPUT CUT AND INSULATE THE WHITE YELLOW WIRE NEXT TO WHITE GRAY WIRE 01 BROWN BLACK PARKING LIGHT OUTPUT 02 GRAY R...

Page 13: ...rn key to ON position LED will turn solid RED Within 5 seconds LED will flash GREEN rapidly Turn key to OFF position Remove key Press UNLOCK on the OEM remote If vehicle is not equipped with OEM remot...

Page 14: ...anual for alternate valet mode programming Insert key into ignition Time restriction Complete next step within 7 seconds Turn key to OFF position then to ON position five times 5x rapidly Wait LED 1 w...

Page 15: ...equal amount of times continuously TO ACCESS THE SETTINGS Press and hold programming button until LED 1 turns solid GREEN LED 1 will flash GREEN as many times as the current or default setting number...

Page 16: ...FIRST PRESS 01 oFF 02 ON 05 TAKEOVER 01 enabLe 02 DISABLE 06 N A 01 N A 07 FACTORY KEYLESS RS SEQUENCE 01 DISABLE 02 N A 03 LOCK UNLOCK LOCK 04 LocK LocK LocK 08 MODULE RUN TIME 01 03 MIN 02 05 MIN 0...

Page 17: ...R 01 DoubLe LocK 02 LOCK UNLOCK 03 LOCK UNLOCK START 04 DOUBLE LOCK START 15 HORN CHIRPS WIDTH 01 30 msec 02 15 mSec 03 60 mSec 02 07 Technical Support only 01 N A 01 N A Vehicle will shutdown when a...

Page 18: ...the parking lights will flash X number times to indicate an error code See table 05 Engine tach signal is lost 06 System is in Valet Mode 07 Vehicle is moving VSS 08 Glow plug timeout error 09 RS not...

Page 19: ...rammed Solid RED Module incorrectly programmed Flashing GREEN Module correctly programmed and operational Solid GREEN then OFF Reset in progress OFF Invalid ground when running status from remote star...

Page 20: ...ile connecting the BLACK 20 PIN connector Wait LED 1 will flash RED RELEASE programming button LED 1 will turn RED for 2 seconds Module RESET completed Reconnect all connectors Repeat programming proc...

Page 21: ...start sequence Press unlock on OEM or aftermarket remote Insert key into ignition Turn key to ON position Press and release BRAKE pedal Take over procedure completed Failure to follow procedure will r...

Reviews: