Have the gas supply line installed in accordance with local codes, if any. If not available, follow ANSI 223.1.
Installation should be done by a qualified installer approved and/or licensed as required by the locality (
in the Commonwealth
of Massachusetts installation must be performed by a licensed plumber or gas fitter
).
ORIFICE SIZE
Flare Fireplace appliances are tested and approved for installations at elevations of 0
–
4500 feet (0
–
1372 meters) above sea
level using the standard burner orifice sizes. At the time of installation, it must be determined if the appliance needs to be de-
rated. Contact your local gas supplier for deration requirements for your area.
De-rated installation consideration can start at 2000 Ft above sea level.
At higher elevations, the amount of BTU fuel value delivered must be reduced by either using gas that has been de-rated by
the gas company or by changing the burner orifice to a smaller size as regulated by the local authorities having jurisdiction and
by the (USA) National Fuel Gas Code NFPA 54/ANSI Z223.1 - latest edition or in Canada, the CAN/CSA-B149.1 code
–
latest
edition.