background image

Air TreATmenT

Housing venTilATion

Air ComforT

» Technical Manual

Cooker hood CPd

Summary of Contents for CPdb

Page 1: ...Air Treatment Housing ventilation Air Comfort Technical Manual Cooker hood CPD...

Page 2: ...out supervision Maintenance for the user Cleaning 3 Replacing of the low energy lamp 3 General 3 Operating of CPDA and CPDJ 4 Operating of CPDB CPDC CPDG CPDH CPDK 5 INSTALLATION FOR INSTALLERS AND SE...

Page 3: ...Check the grease filter every week Clean if needed Note Do not use the cooker hood without grease filter fitted General There is a fire risk if cleaning is not carried out in accordance with the inst...

Page 4: ...Cooker hood CPD Technical manual 4 Fl kt Woods 8757 GB 2016 12 05 Specifications are subject to alteration without notice Maintenance Operating of CPDA and CPDJ Handle for boosting Lighting...

Page 5: ...l kt Woods 8757 GB 2016 12 05 Specifications are subject to alteration without notice NORMAL MIN MAX MIN 1 2 MIN 1 2 MIN 1 2 Maintenance Operating of CPDB CPDC CPDG CPDH and CPDK Handle for boosting L...

Page 6: ...ts service agent or similarly qualified persons in order to avoid hazard The distance between the stove and the lower edge of the cooker hood has to be at least 400 mm recommended distance 500 mm When...

Page 7: ...160 100 a min 500 mm a 700 a 600 a 500 200 100 100 415 365 365 255 205 205 INSTALLATION FOR INSTALLERS AND SERVICE PERSONNEL CPDA Intended for multiple unit dwellings with a central extract air fan o...

Page 8: ...for older exhaust air fan JBDD aa with capacitor box manufactured before 2007 JBDD aa earlier version CPCB JBDD aa earlier version a a b b CPDC Replacement hood for older heat recovery unit RDKG with...

Page 9: ...xhaust air fans and units for example JBDB JBDC and RDAA INSTALLATION FOR INSTALLERS AND SERVICE PERSONNEL 50 176 115 33 96 min 500 mm 160 2 3 1 JBDD 1 2 1 Orange Supply voltage to fan 2 Blue Neutral...

Page 10: ...e subject to alteration without notice CPDH Replacement hood for older heat recovery units RDKG with bypass Fits RDKG a 2 c d 1 a b CPDK For heat recovery unit RDKG Fits RDKG a b c d 2 a b INSTALLATIO...

Page 11: ...ect to alteration without notice INSTALLATION FOR INSTALLERS AND SERVICE PERSONNEL CPDJ For heat recovery unit RDKR or RDKS a b 3 2 1 RDKS RDKS 4 5 4 1 4 2 7 6 It is important to seal the grommet by p...

Page 12: ...ecovery Unit RDAA 1 Not for conversion kit JBDB 99 05 0 JBDB1 CPDG CPTG Supply 230V JBDA 99 031 2 F not included N L Blue Blue White Black Black Yellow Green Yellow Green Orange JBFG CPDG CPTG Supply...

Page 13: ...12 05 Specifications are subject to alteration without notice Adjustment b c a Pa a 7 5 10 12 5 15 20 25 250 200 100 50 40 30 5 6 7 8 9 10 12 15 20 30 Air flow q l s Measuring pressure p m Pa 30 30 1...

Page 14: ...hout notice CPDA CPDB CPDC and CPDG Forced ventilation When adjusting the forced air flow the fan speed must be increased up to the forced flow 10 20 30 40 50 100 200 150 20 30 40 50 80 Air flow q l s...

Page 15: ...ny number of plugs in the cover plate 1 2 3 4 5 6 7 8 9 10 p 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 30 10 8 6 4 2 Air flow q l s Measuring pres...

Page 16: ...thout notice CPDH and CPDK Forced ventilation Damper blade without basic flow valve sealed damper blade When adjusting the forced air flow the fan speed must be increased up to the forced flow Adjustm...

Page 17: ...mm R L 700 mm R x x x x x x x 5 1 CPDA 99 10 Timer with shaft 500 mm M 600 mm M 700 mm M L x x x 5 1 CPDJ 99 01 Timer w shaft 600 700 mm w contact function x 6 10 CPCA 99 09 Lamp socket x x x x x x x...

Page 18: ...machinery electrical equipment of machines general requirements EN 60335 1 Household and similar electrical appliances Safety Part 1 General requirements EN 60335 2 31 Household and similar electrica...

Page 19: ...sorted Depending on what product it is may not all parts components materials be rep resented Printed circuit boards cables batteries motors sensors etc Filters except made of pure metal in cooker hoo...

Page 20: ...utions We specialize in the design and manufacturing of a wide range of products and solutions for Air Movement Air Treatment Air Distribution Air Management and Air Diffusion with focus on two major...