Row
-DENCO
Technical Data
FläktGroup DC-2014-0106-GB 2019-02/R3 • Subject to modifications
21
5
Technical Data
5.1
Row
-DENCO DX rack cooler
Tab. 5-1
1 Inside conditions: air 35 °C/27 % RH - Outside air temp.: 35 °C
2 Measured at a height of 1.5 m and 2 m from the front of the unit in a free field
3 1200 mm DEEP RACK ONLY
DRX
051
071
121
Power supply
V-Ph~Hz
230/1N/50-60
230/1N/50-60
230/1N/50-60
Refrigerant
R410A
R410A
R410A
No. of circuits
No.
1
1
1
CAPACITY DELIVERED
MAX
MIN
MAX
MIN
MAX
MIN
Total capacity (1)
kW
10,63
4,72
16,59
6,78
28,62
11,76
Sensible capacity (1)
kW
9,61
4,72
15,67
6,78
27,37
11,76
SHR
0,90
1,00
0,94
1,00
0,96
1
FANS
Fan air flow-rate
m²/h
1500
900
2700
1200
4200
1800
EC radial fan power consumption
kW
0,16
0,04
0,304
0,064
0,86
0,09
No. of EC radial fans
No.
2
4
5
Std. available static pressure
Pa
20
20
20
SOUND DATA
Sound pressure (2)
dB(A)
60
61
66
AIR FILTER
Filtration grade
G2
G2
G2
REFRIGERANT CONNECTIONS
Refrigerant connections (ODS Ø)
IN - LIQ
12
16
18
OUT-GAS
18
22
28
HUMIDIFIER (3)
Capacity
kg/h
3
3
3
DIMENSIONS
Length
mm
300
300
300
Depth
mm
1000/1200
1000/1200
1000/1200
Height
mm
2085
2085
2085
DROU
051
071
121
Power supply
V-Ph~Hz
230/1N/50
400/3N/50
400/3N/50
COMPRESSORS
MAX
MIN
MAX
MIN
MAX
MIN
No. of compressors
No.
1
1
1
Compressor power consumption (1)
kW
2,63
0,77
4,56
1,17
7,19
1,81
FANS
Fan air flow-rate
m
3
/h
6400
8640
15768
Fan power consumption
kW
0,31
0,60
1,20
No. of fans
No.
2
1
2
REFRIGERANT CONNECTIONS
Refrigerant connections (ODS Ø)
IN - GAS
3/4" SAE -18
22
28
OUT-LIQ
3/8" SAE - 12
16
18
SOUND DATA
Sound pressure (2)
dB(A)
54
61
64
DIMENSIONS
Length
mm
900
1450
1450
Depth
mm
420
550
550
Height
mm
1240
1200
1700