Maintenance of the AP BIO
AP BIO
400/500/1000/2400
26
FG-DC_10523-GB_AP Bio_IOM-R0-12/2020 • Subject to modifications
9.1.2 Replacing the filters AP BIO 2400
Fig. 9-3
Open the AP BIO 2400
•
Unlock the door with a special access key on the middle right side.
•
Open the first door by pressing with both hands on the door at the points shown in
Fig. 9-3.
Fig. 9-4
Replacing the AirFend filter AP BIO 2400
1: Lever
2: Filter quick release
3: Filter (ISO ePM1 55% (F7) + H14)
•
Swing the lever (1) of each of the 4 AirFend filter quick-releases (2) and rotate them
90°.
•
Open the plastic bags, remove the new filters and put them aside.
•
Extract the used filters (3) from the unit one at a time, put these into the empty plastic
bags of the new filters and seal up with a tape.
•
Clean inner flat surfaces
carefully with a cloth and disinfect with spray, observe the
exposure time of disinfection liquids of min. 30 sec. Also refer to “Cleaning the air
purifier” on page 27.
•
Reassemble the new filters in the reverse order.
•
Close the access door and repeat the procedure on the opposite side.
Door