NOISE AND VIBRATION LEVEL DECLARATION (Max. value)
EN 60745-2-2
FLAIR : AT12H14, AT12S38, AT16H14, AT 16S38
Sound pressure level (no load) L
pA
: 66.7 dBA Uncertainty K : 1.5 dB
Sound power level (no load) L
wA
: 77.7 dBA Uncertainty K : 1.5 dB
Vibration total value (no load) a
hd
: 0.6 m/s
2
Uncertainty K : 1.5 m/s
2
FLAIR: AT30S38, AT35S38
Sound pressure level (no load) L
pA
: 67.8 dBA Uncertainty K : 1.5 dB
Sound power level (no load) L
wA
: 78.8 dBA Uncertainty K : 1.5 dB
Vibration total value (no load) a
hd
: 0.3 m/s
2
Uncertainty K : 1.5 m/s
2
The declared noise levels and vibration total value has been measured in
accordance with a standard test method and may be used for comparing one tool
with another. The declared noise levels and vibration total value may also be used in
a preliminary assessment of exposure.
WARNING:
− The noise and vibration emission during actual use of the power tool can differ
from the declared total value depending on the ways in which the tool is used; and
− Need to identify safety measures to protect the operator that are based on an
estimation of exposure in the actual conditions of use (taking account of all parts of
the operating cycle such as the times when the tool is switched off and when it is
running idle in addition to the trigger time).