Description
Assembly
Assembly instructions
Safety information
• Electrical work and repairs must be
performed by a qualified electrician.
• During installation, always observe
the national installation regulations.
• The luminaire must not be modified
in any way. Risk of electric shock
and accident.
• The light source of this luminaire
is not replaceable; when the light
source reaches its end of life the
whole luminaire shall be replaced.
Technical data
1
Power supply terminal
2
Wall mount
3
Luminaire body
4
Wrench
5
2 x Fastening screws
6
2 x Screws / plugs
7
Sealing
1.
Unscrew the fastening screws using
the provided wrench and remove the
wall mount.
2.
Select an installation location without
pipes or cables behind it. Mark the
holes and drill the holes.
3.
Lead the cable through the cable
hole and then fix the wall mount in
place with screws and plugs.
Caution: Make sure the screws
and plugs are suitable for the
wall material.
4.
Connect the cables to the terminal
block (see section III).
5.
Attach the luminaire to the wall
mount with the sealing in place.
Tighten the fastening screws using
the provided wrench.
6.
Connect the power supply.
Nominal voltage:
220-240 V~,
50-60 Hz
Rated power:
13.5 W
Protection class:
I /
Degree of protection: IP54
Color temperature: 3000 K
Light source:
LED non-
replaceable!
Luminous flux:
1500 lm
Size:
170x48x180 mm
Used symbols
Caution: Risk to health and the
product.
Class I appliance. Must be
connected to a protective
ground.
Caution: Risk of electric shock.
Caution: First disconnect the
power supply for this connection.
Please read these instructions
carefully and keep them safe for
later use!
19
ENGLISH
GB
Connection
III.
Waste disposal
The pictogram with the
crossed out dustbin points to
the requirement for separate
disposal of electrical and electronic
appliances (WEEE). Electrical and
electronic appliances can contain
hazardous and environmentally
hazardous materials. Do not dis-
pose of this appliance as domestic
waste. Hand it in at a collection
point for electrical and electronic
waste. By doing so, you will help to
conserve resources and protect the
environment. For further details,
please consult your local authori-
ties.
Lead the cable through the cable hole.
Connect the cables to the terminal
block. Make sure that the connections
are tight and that no loose cable
endings emerge from the terminal.
Tighten the screws and close the cover
of the terminal. The product needs to be
earthed.
L: Brown
: Yellow/Green
N: Blue
Maintenance and care
IV.
Caution: Let the luminaire cool
down before cleaning.
Cleaning
Wipe the luminaire with a soft, dry cloth
only. Never use scouring powders or
chemical cleaning agents. Never allow
the electrical components to become