background image

 

 

FSSASD-R_G220v.PUB 

Rev. G  -01/10 

ELECTRONIC AIR CLEANER 

LIMITED FIVE (5) YEAR WARRANTY

 

 

FIVE  YEAR  WARRANTY  - 

This  FIVE  SEASONS  product  is  warranted  to  be  free  from  electrical  and  mechanical 

defects in material and  workmanship, under normal use and maintenance  within its listed capacity, for a period of 
FIVE (5) years from the date of original purchase.  The FIVE SEASONS product must not have been moved from the 
site  of  original  installation.    A  new  or  remanufactured  part  to  replace  the  defective  part  will  be  provided  without 
charge  for  the  part  itself,  through  an  authorized  FIVE  SEASONS  service  dealer,  provided  the  defective  part  is 
returned  to  the  FIVE  SEASONS  distributor 

prepaid

.    The  replacement  part  assumes  the  unused  portion  of  the 

warranty.  

Proof  of  Purchase  and  Installation

 must be provided.  Failing this, FIVE SEASONS will guarantee the 

unit for a period of sixty (60) months from the date of manufacture, according to the manufacturer’s records.  The 
warranty does not include the prefilters, carbon filters or ionizing wires. 
 

THIS WARRANTY DOES NOT INCLUDE ANY ADDITIONAL LABOR ALLOWANCE OR OTHER COSTS

 incurred 

for diagnosis, repairing, removing, installing, shipping, servicing, or handling of either defective parts or replacement 
parts.  Such costs may be covered by a separate warranty provided by the dealer. 
 

LIMITATIONS  OF  WARRANTY 

- All implied warranties (including implied warranties of merchantability) are hereby 

limited  in  duration  to  the  period  for  which  the  limited  warranty  is  given.    The  expressed  warranties  made  in  this 
warranty  are  exclusive  and  may  not  be  altered,  enlarged,  or  changed  by  any  distributor,  dealer  or  other  person 
whatsoever. 
 

FIVE SEASONS COMFORT LIMITED WILL NOT BE RESPONSIBLE FOR: 

1.  Normal maintenance  as  outlined  in  the  Owner’s  Manual  including  cleaning  of  electronic  collecting  cells  and/or 

replacement of carbon filters. 

2.  Damage or repairs required as a consequence of faulty installation or application by others. 
3.  Damage  or  repairs  needed  as  a  consequence  of  any  misapplication,  negligent  handling,  improper  servicing, 

unauthorized alteration, or improper operations. 

4.  Failure  to  start  due  to  voltage  conditions,  blown  fuses,  open  circuit  breakers  or  other  damages  due  to  the 

inadequacy or interruption of electrical service. 

5.  Damage as a result of floods, winds, fires, lightning, accidents, corrosive atmosphere, or other conditions beyond 

the control of FIVE SEASONS COMFORT LIMITED. 

6.  Parts not supplied or designated by FIVE SEASONS COMFORT LIMITED. 
7.  FIVE  SEASONS  COMFORT  LIMITED  products  installed  outside  the  continental  U.S.A.,  Alaska,  Hawaii,  and 

Canada. 

8.  Any personal injury, special indirect or consequential property or commercial damage of any nature whatsoever. 
 
 

Model No. 

 

 

 

 

 

Serial No. 

 
Date Of Installation 

 

 

 

 

Installed By 

 
Owner’s Name & Address 

 

 

RETAIN THIS CERTIFICATE WITH YOUR VALUABLE DOCUMENTS 

FIVE SEASONS COMFORT LIMITED 

351 North Rivermede Road, Concord, Ontario, Canada  L4K 3N2 

Tel:  (416) 213-5636                Fax:  (416) 213-5593 

Toll Free North America:  1-800-267-8305 

Email:  [email protected] 

Web:  www.fiveseasonsaircleaners.com 

ATTENTION INSTALLING CONTRACTOR:  IF FAILURE SHOULD OCCUR, DO NOT RETURN PRODUCT TO THE 

DISTRIBUTOR.    CALL  THE  TOLL-FREE  HOTLINE  1-800-267-8305 
FOR TECHNICAL ASSISTANCE. 

Summary of Contents for SASD10-2

Page 1: ...i bacteria viruses and more down to 0 01 micron Dual Voltage Aluminum Collecting Cells are durable and easy to maintain Cell Guide ensures proper placement of collecting cells Activated Carbon Filters remove unpleasant odors Electronic Air Proving Switch for quick wiring optional Dual Indicator Lights show Air Cleaner is working at a glance Galvanized Steel Cabinet for solid vertical or horizontal...

Page 2: ...e of electrostatic precipitation Millions of airborne pollutants are carried through the return air ducts of the heating cooling system and treated through four stages of filtration The prefilters 2 remove all large visible particles such as lint Smaller particles then pass through a two stage electrostatic collecting cell 2 First particles are given a powerful positive electrical charge by the io...

Page 3: ...ir Cleaner will vary with CFM and whether the optional carbon filters have been installed in the unit Location The Air Cleaner must only be installed in the return air duct as close to the fan compartment as possible This location provides the most even airflow across the collecting cells and allows the Air Cleaner to keep the system motor and blower clean The installation can be vertical or horiz...

Page 4: ...ype humidifier must be installed as far from the Air Cleaner as possible 2 Collecting cells must be washed frequently to prevent a mineral deposit build up Installation Location With Air Conditioner Whenever possible the Air Cleaner should be installed upstream of the cooling coil This location will clean the air before it reaches the evaporator coil 4 MODEL DIMENSIONS in cm A B C D E F G H SASD10...

Page 5: ...ent direction than the left to right set up The handle should face the door Close access door Wiring Wiring should only be performed by qualified personnel only All wiring must comply with all applicable codes and standards The voltage of the power source must match the voltage indicated on the Air Cleaner The Air Cleaner must operate ONLY when the system fan is running Make sure the Air Cleaner i...

Page 6: ...with DAX Detergent or a non chlorine non corrosive non abrasive liquid household detergent Allow detergent to run down both sides of plates and ionizing wires Let stand for 5 minutes or fill up laundry tub with water and DAX Detergent and dunk cells up and down until water is dirty 3 Rinse cells well with hot water maximum 120 F 49 C 4 To remove contaminate from the ionizing wires use an old tooth...

Page 7: ...e from the power board Measuring High Voltage At Power Board A high voltage meter capable of measuring up to 10 000 VDC is required to test the voltage 1 The Air Cleaner should be ON with the cells installed the door closed and the system fan running The Air Cleaner should be on at least 5 minutes to allow voltage to stabilize The cells and ionizing wires must be clean 2 Remove the cover from powe...

Page 8: ...board is turned on and the performance light will come on The light on the power switch will be lit even when the APS is open If the power board fails to come on with the fan on check that the sensor is properly set down to the bottom of the plastic bushing in the front of the power box To check the APS for proper operation remove the collecting cells turn the unit ON without the fan on The power ...

Page 9: ... voltage meter 9 Replace the power box cover 10 Turn ON the Air Cleaner Setting Approximate Voltage Without High Voltage Meter A high voltage meter should be used to set the high voltage If one is not available this method can be used This will only set an approximate voltage After using this method the voltage should be reset with a high voltage meter as soon as possible 1 Remove power box cover ...

Page 10: ...ove it from the cabinet 6 If you are removing the power box for any length of time tape a cover over the top opening to prevent air from entering into the system Replacing A Tungsten Ionizing Wire Replacement wires are cut to the correct length and have eyelets at each end for easy replacement 1 Turn OFF power to Air Cleaner 2 Remove cell from Air Cleaner 3 Remove all parts of broken wire from the...

Page 11: ...9 D1 0509 D0 0509 D1 0509 11 Power Box Complete No Cover Depends on options with power box 12 Carbon Filters Set of 3 1156 3 1156 3 1856 3 1856 3 13 Prefilter R0 0855 R1 0855 R2 0855 R8 0855 14 Cell Guide Plastic R1 0603 R1 0603 R1 0603 R1 0603 15 Collecting Cell D0 0400 D1 0400 D2 0400 D8 0400 16 Cell Handle R1 0484 R1 0484 R1 0484 R1 0484 17 Door with Plastic Clip Handle D0 0632 D1 0632 D2 0632 ...

Page 12: ...h needle nose pliers gently pull contacts down or replace contacts Cells arcing excessively power light and per formance indicator light ON or flashing Cells wet from washing Allow cells to dry completely Particles lodged in cell or broken ionizing wire Wash cell Shake particle out of cell Replace wire if necessary Ducts were not cleaned prior to installation of air cleaner Clean ducts Cell plates...

Page 13: ...r basis for the Air Cleaner to function at its peak efficiency The frequency of cleaning will vary from one house to another On average the cells should be cleaned every 3 months Use the chart below to keep track of your cleaning schedule DATE CLEANED DATE CLEANED DATE CLEANED 13 ...

Page 14: ...NOTES 14 ...

Page 15: ...anties made in this warranty are exclusive and may not be altered enlarged or changed by any distributor dealer or other person whatsoever FIVE SEASONS COMFORT LIMITED WILL NOT BE RESPONSIBLE FOR 1 Normal maintenance as outlined in the Owner s Manual including cleaning of electronic collecting cells and or replacement of carbon filters 2 Damage or repairs required as a consequence of faulty instal...

Page 16: ...d of the furnace or air handler ensure that there is 220 Volt output from these terminals when the unit is run manually and is running on low speed Some manufacturers do not supply full output voltage to the terminals in the low speed mode so the Air Cleaner will not function The green Performance Indicator Light will not turn on The Air Cleaner performs best when the system fan is on FAN ON or Co...

Reviews: