background image

ADMINISTRATOR MANUAL

Dispensing Innovation™

Priming/Dispensing 

Only Setup Guide

P

R

IM
E •

 D

ISP
ENS

E

Summary of Contents for AIRFREE LDS9000

Page 1: ...ADMINISTRATOR MANUAL Dispensing Innovation Priming Dispensing Only Setup Guide PRIME DISPENSE...

Page 2: ...3 Fishman Corporation USA Toll Free 1 800 433 2115 Fishman Corporation USA Toll Free 1 800 433 2115...

Page 3: ...FLUID DISPENSING This setup guide is designed to help Administrators program SmartDispenser system as Prime Only and Dispense Only units If you are unsure of any step or have questions consult your Sm...

Page 4: ...your SmartDispenser 5 System 3 0 Hook up your SmartDispenser 6 components 4 0 Startup and Logon the 9 ProcessControl2 Mode of SmartDispenser 5 0 LDS Push To Connect 15 Gun Assembly 6 0 Attach the Geni...

Page 5: ...You will not need compressed air The SmartDispenser works without air 1 2 The SmartDispenser utilizes a WiFi USB WiFi adapter included or Ethernet connection via the back panel for networking App down...

Page 6: ...00 433 2115 3 0 Hook up your SmartDispenser components 3 1 Refer to the diagram to connect all components and peripheral devices to the SmartDispenser 6 Fishman Corporation USA Toll Free 1 800 433 211...

Page 7: ...B Gun Connector C Foot Pedal D Foot Pedal Connector E Keyboard F Mouse G USB connectors H Ethernet Port I Cisco Wireless Connectivity Device J Video Camera K Power Cord L Universal Power Supply M Powe...

Page 8: ...twork using the Ethernet port H found on the back of the unit If you have a wireless network install the supplied wireless connectivity device I in one of the USB connectors G located on the front and...

Page 9: ...Startup and Logon to the LDS9000 Traditional Mode of SmartDispenser 4 1 Press the black startup button N on the front of the SmartDispenser The green power light will illuminate O The Windows 7 operat...

Page 10: ...t down the SmartDispenser you can do so by simply pressing the black start button to initiate the proper shut down sequence of the Windows 7 operating system 4 3 In a few moments you will be required...

Page 11: ...LDS9000 Traditional mode icon 4 5 On SmartDispenser Logon screen select Administrator from drop down menu Tap click password 1234 tap click OK tap click Logon button Access the Admin button and selec...

Page 12: ...reen and or the mouse to use the arrow to click on program parameter input boxes 1 Tap click the input box left right arrows will appear Tap click either arrow to increase or decrease the number 2 Tap...

Page 13: ...R button and input the desired number Tap click Enter button Upon tap click of Enter button the keypad will automatically move to the next dispense parameter Tip Use the four arrow keys to move up and...

Page 14: ...utomation system units Any Dispense Volume can be chosen as you will only be utilizing the MANUAL Auto setting Select a Speed setting that is approximately 25 of the fastest rate Be certain that the d...

Page 15: ...ssembly 5 1 The LDS Push to Connect dispense gun are available in different configurations LDAV Large Dot Any Viscosity MDAV Medium Dot Any Viscosity SDAV Small Dot Any Viscosity The gun connectors ar...

Page 16: ...the dispensing gun with the piston hub pointed upward place the barrel reservoir over the piston hub of the dispensing gun 6 3 Holding both barrel reservoir and dispense gun loosely step on the foot...

Page 17: ...he EXTEND Retract button to RETRACT Extend and step on the foot pedal to bring the ears completely flush to the retaining plate If you set the switch to RETRACT Extend be sure it is set back to EXTEND...

Page 18: ...ense gun in an automated environment secure the Dispense Tip Locator to the gun mount bracket with the screws provided and follow these steps before priming the dispense tip 7 2 Adjust the thumb screw...

Page 19: ...national 00 1 508 435 2115 www fishmancorp com 19 7 3 Engage the tip locator arm by lifting it 90 and lock it in place 7 4 Use the thumb screw on the arm to make micro height adjustments 7 3 Tip Locat...

Page 20: ...height Gently tug the tip locator arm to disengage and remove the LDS dispense gun 7 6 Add a second LDS dispense gun with filled syringe and dispense tip and lock the locator arm in place If necessar...

Page 21: ...ional 00 1 508 435 2115 www fishmancorp com 22 EXTEND International 00 1 508 435 2115 www fishmancorp com 21 7 7 Gently tug the tip locator arm remove the LDS dispense gun and continue to repeat as ne...

Page 22: ...same dispense tip being used on the automation system 8 2 Hold the dispense tip over the provided dot chart as shown press the foot pedal intermittently until the fluid begins to flow towards the end...

Page 23: ...TRACT Extend 8 5 Step on the foot pedal in small short pulses until the fluid stops flowing from the tip Goal To stop the forward motion of the fluid by retracting the piston and sucking the fluid bac...

Page 24: ...artDispenser Setup 9 1 Insert USB Stick Press Prime Done Again 9 2 1 Tap click the Prime Done button You will be prompted to insert a USB stick Allow a few seconds for the SmartDispenser to recognize...

Page 25: ...timal performance can only be achieved by matching the precise step count for the dispense gun and syringe barrel to the specific SmartDispenser 9 2 3 If you are providing primed guns for multiple P T...

Page 26: ...ly select Serial Interface as a means of transferring step count Connect the units via a 9 pin Null Modem Serial Cable 9 3 3 Perform priming steps with the dispense gun and syringe barrel in the same...

Page 27: ...tion 9 4 1 The Dispense Only unit can be set to either the Traditional LDS9000TM or Process Control2 screen with the designated dispense program The step count in the illustration on the right should...

Page 28: ...spense gun and syringe barrel in the same manner described in steps 9 2 through 9 2 3 When completed record step count manually pen and paper for example 9 5 3 If you are providing primed guns for mul...

Page 29: ...y unit The saved step count information for each gun can vary slightly Optimal performance can only be achieved by matching the precise step count for the dispense gun and syringe barrel to the specif...

Page 30: ...portion of this manual may be reproduced in any form Fishman SmartDispenser Genius AirFree PosiLok FreeFlow SafeLok SurLok DripFree LDS LDS9000 Push To Connect and ProcessControl2 are all trademarks o...

Page 31: ...International 00 1 508 435 2115 www fishmancorp com 32 International 00 1 508 435 2115 www fishmancorp com 32...

Page 32: ...33 2115 Fishman Corporation USA Toll Free 1 800 433 2115 Fishman Corporation 192 South Street Hopkinton MA 01748 United States www fishmancorp com US Canada 800 433 2115 United Kingdom 1905 456008 Eur...

Reviews: