Fisher FSLI-180B Operating And Installation Instruction Manual Download Page 1

Operating and Installation Instructions Manual

DC Inverter Ducted Air Conditioning Unit

-

(2.6-16kW)

Thanks for your selection of

Ducted Air Conditi

-

oning Unit Before use please read this

.

,

instruction manual carefully and keep it properly

.

to ensure correct use of this machine

Unit Model

:

indoor unit

outdoor unit

FSOI-180B

FSLI-180B

FSOI-240B

FSLI-240B
FSLI-450B-H
FSLI-600B-H

FIHSER

-3F

FSOI-450B-3F
FSOI-600B-3F

Summary of Contents for FSLI-180B

Page 1: ... for your selection of Ducted Air Conditi oning Unit Before use please read this instruction manual carefully and keep it properly to ensure correct use of this machine Unit Model indoor unit outdoor unit FSOI 180B FSLI 180B FSOI 240B FSLI 240B FSLI 450B H FSLI 600B H FIHSER 3F FSOI 450B 3F FSOI 600B 3F ...

Page 2: ...8 Installation Dimension of Indoor Unit 22 Installation of Outdoor Unit 24 Precautions on Installation of Indoor Unit and Outdoor Unit 26 Indoor Unit Level Inspection and Air Duct Installation 26 Installation and T est of Condensing Water Pipe and Selection of Connecting Pipe 28 Installation of Connecting Pipe 29 Position and Method of Installing Wire Controller 31 Connection of Cables 33 Troubles...

Page 3: ... by professinal Before use please check and confirm if the cables drainage pipes and pipelines are correctly connected hence to eliminate the risk of water leakage refrigerant leakage el ectric shock or fire Main power must be securely earthed to ensure effec tive grounding of air conditioner unit and avoid the risk of electric shock Please do not connect the earthing cable to coal gas pipe water ...

Page 4: ...ng status display 4 Energy saving status display 5 Set temperature display 6 Ambient temperature display 7 Fresh air status display not supplied 8 Mode cooling dehumidifying fan heating auto 9 Failure status display 10 Sleep status display 11 Mode key 12 Set temperature increase key 13 Set temperature decrease key 14 Fan speed key fresh air setting 15 Sleep key outdoor environment temperature chec...

Page 5: ...sing the keys once the temperature shall increase or decrea se by1 C NOTE key lock function whenthe and key arepressed simultaneously for 5 second the set temperature indicatingarea shall display EE and all keys response shall be shut off press the two keys simultaneously for 5 second again the key lock function shall be relea sed When the wire controller is lockedbyremote monitor or centralized c...

Page 6: ...oduce cooling effect but shall only operate under Fan mode When the unit operates under Dehumidifying mode DRY shall be displayed Now the interior fan shall operate in the manner of low speed air supply within a certain range of temperatures The dehumidifying effect of this mode is better than that of the Cooling mode and saves more energy When the unit operates under Heating mode HEAT shall be di...

Page 7: ...r 30 minutes 06 The unit operates continually for 60 minutes and the fresh air valve opens for 36 minutes 07 The unit operates continually for 60 minutes and the fresh air valve opens for 42 minutes 08 The unit operates continually for 60 minutes and the fresh air valve opens for 48 minutes 09 The unit operates continually for 60 minutes and the fresh air valve opens for 54 minutes 10 Fully open A...

Page 8: ...nds afTER THE LAST KEY INPUT AND THE NORMAL SHUTOFF STATUS INTERFACE SHALL BE DISPLAYED FTER THE ABOVE SETTINGS ARE COMPLETED THE SYSTEM SHALL DISPLAY h3 6 v OW THE SET TEMPERATURE SHALL NOT EXCEED THE TEMPERATURE RANGE OF THE ENERGY SAVING SET TING BEFORE OR EXAMPLE THE LOWER COOLING LIMIT IS SET AS AND THE UPPER COOLING LIMIT IS SET AS FOR THE ENERGY SAVING TEMPERATURE SETTING IN SO THE COOLING ...

Page 9: ... from the following two settings The indoor room temperature is measured at the air intake Now the OUT ENV area displays 01 The indoor room temperature is measured at the wire controller Now the OUT ENV area displays 02 The default room temp sensor is located at the air intake The indoor room temperature is measured at the wire controller when the mode is heating or auto At other modes it is measu...

Page 10: ...e F0 Failure of Indoor Room Sensor at Air Intake E1 Compressor High Pressure Protection F1 Failure of Evaporator Temp Sensor E2 Indoor Frost Proof Protection F2 Failure of Condenser Temp Sensor E3 Compressor Low Pressure Protection F3 Failure of Outdoor Ambient Sensor E4 Compressor Exhaust High Temperature Protection F4 Failure of Exhaust Temp Sensor E5 Compressor Overheat F5 Failure of Indoor Roo...

Page 11: ...right Dark Blink E5 Malfunction from driving part to main control communication P6 Bright Bright Dark Dark Dark Blink E5 IPM module protection H5 Bright Blink Blink Bright Bright Bright E5 Compressor overspeed LF Bright Blink Blink Bright Bright Dark E5 Sensor connection protection Pd Bright Blink Blink Bright Bright Blink E5 Temperature drift protection PE Bright Blink Blink Bright Dark Bright E5...

Page 12: ...nt protection input side PA Bright Blink Bright Blink Bright Dark E5 Driver board environment temperature sensor malfunction PF Bright Blink Bright Blink Dark Bright E5 AC input voltage abnormality PP E5 Electrification loop malfunction PU E5 Note 1 No indicator LED6 for FSOI 180B 11 ...

Page 13: ... can be as far as 8 meters Never drop or throw at will the remote controller Never let any liquid enter the remote controller Avoid direct sunshine over the remote controller Do not place the remote controller in an extremely hot place Precautions Press FAN button set fan speed Press TEMP button set suitable TEMP Press MODE but ton to set operation mode Plug in press ON OFF button then air condi t...

Page 14: ...perature key to adjust the set temperature for the room Under the heating mode the unit has the functions of preventing cold air supply and supplying remaining heat After the startup of the compressor the indoor fan shall start operation when the evaporator temperature is larger or equals 35 or after the unit has be started for 45 secon ds so as to avoid supply of cold air shortly after the unit i...

Page 15: ...f you press the ON OFF key b Press the mode key and select the mode c Press the temperature key and set the temperature as required Fan Mode Operation Connect the unit to power supply Press the ON OFF key Press the MODE key to select FAN mode The unit shall operate under FAN mode Press the FAN key to select from high medium and low speed a After the unit is connected to power supply the air condit...

Page 16: ...er codes of all functions The life of batteries is about 1 year Do not mix new and old batteries or mix different types of batteries in usage If the remote controller shall not be used for a long time take out the batteries to avoid liquid leakage and any subsequent failure Load two AAA batteries Accessories 15 ...

Page 17: ...alized controller weekly timer The weekly timer has the function of invalidating the lower unit The weekly timing fun ction is able to realized four timing ON OFF periods for any unit every day so as to achieve fully automatic operation This WEEKLY TIMER adopts 485 mode to communicate with manual control of every duct type unit and it can control up to 16 units Adopting 2 core twisted pair wire th...

Page 18: ...s know your requirement before your placing the order for this WEEKLY TIMER will only be prepared when customer orders communication joint with WEEKLY TIMER on manual control had been prepared 1 Press or to select the unit that needed to be control It is available to control several units by Group Control 1 16 or control single unit by Single Control 2 When selected a certain or several units by S...

Page 19: ...ergy savingstatus display 5 Set temperature display 6 Ambienttemperature display 7 Fresh air status display not supplied 8 Mode cooling dehumidifying fan heating auto 10 Sleep status display 11 Mode key 12 Set temperature increase key 13 Set temperature decrease key 14 Fan speed key fresh air setting 15 Sleep key outdoor environmenttemperature check 16 Timing key 17 ON OFF key Composition of wire ...

Page 20: ... timer No matter the unit is turned on or turned off press TIMER button enter into Timer setting then use the buttons to select the time As shown In Fig 15 the setting time Fig 16 or cancel setting Fig 17 Then press Timer Button enter into each item setting Wire controller with week timer function No 1 No17 is the same as front instructions of No18 No 19 fig 15 fig 16 SEG SEG 19 ...

Page 21: ...re are figure blink it can be set up finally press the ON OFF button complete the setting and quit the timer data will be save Fig 18 19 If entered into Timer setting by pressing the Mode button to select the setting item Day Monday to Sunday Hours 0 23 or Minutes 0 59 By pressing buttons to adjust the setting items then press Timer button to confirm or press the Timer button once more to cancel t...

Page 22: ...ressing buttons to select Week then press the Timer button to confirm at this time dd will display or press Timer button to cancel the selected day at this time dd will not display At last press ON OFF button complete setting and quit Fig 21 21 ...

Page 23: ... of users before going out Refer to the section of wire controller instructions for detailed operation Outdoor Room Sensor Outdoor Side Indoor Side Fig 23 22 This series of ducted air conditioning unit has two indoor room sensors One is located at the air intake of the indoor unit and the other one is located inside the wire controller User can select one from the two indoor room sensors on the ba...

Page 24: ...and features very simple operation Refer to the section of wire controller instructions fo r detailed operation Fresh Air Air Supply Pipe Air Intake Pipe Air Valve Outdoor Fresh Air Indoor Side Before startup the unit ple ase remove all the sea ling film on the healthy filter block Fig 24 4 The hea e head of deli d of deli very of th of the conde e condensate drain e drainage pump can re pump can ...

Page 25: ...ofile Dimensions of Indoor Unit Air In take Drainage P ipe Electric Box G as Pipe Liquid Pipe Air Intake F I Fig 26 D C A B F G H I J Drainage Pipe Gas Pipe Liquid Pipe Electric Box Air Intake E Be suit for Fig 27 Be suit for 24 FSLI 180B FSLI 240B FSLI 450B H FSLI 600B H ...

Page 26: ...Pipe Connecting Pipe Gas Pipe Drainage Pipe Outer Diameter Wall Thickness 932 430 738 894 1012 736 738 125 207 266 1 4 1 2 Dimens ion R equirement of the Ins tallation S pace of Indoor Unit Fig 28 Warning The height of installation for the indoor unit should be m abo 2 5 ve Fig 29 Nut with Washer Nut Spring Washer Nut with Washer Nut Spring Washer 3 4 25 Be suit for Be suit for 1011 748 820 1115 1...

Page 27: ...discharged by outdoor unit will not return and that sufficient space for repair shall be provided around the machine The installation site must have good ventilation so that the outdoor unit can take in and exhaust enough air Ensure that there is no obstacle for the air intake and exhaust of the outdoor unit If there is any obstacle blocking the air intake or exhaust remove it Place of installatio...

Page 28: ...rovide enough space for the service and maintenance 5 The installation site must be far away from heat source leakage of inflammable gas or smoke 6 The indoor unit is of ceiling mount indoor unit is hidden inside the ceiling 7 The indoor and outdoor units the power cable and the connecting electrical lines must be at least 1 meter from any TV set or radio This is to avoid image interference or noi...

Page 29: ...pport Place the unit at the beam and fix it Level Check of the Indoor Unit After the indoor unit is installed it is required to check the level of the whole unit The unit must be placed horizontally but the condensate pipe shall be installed obliquely so as to facilitate the drainage of condensate Air Supply Air Intake i Condensate Drainpipe Level Instrument Enlarged View Condensate Drainpipe As t...

Page 30: ... inclining angel of 5 10 so as to facilitate the drainage of condensate The joints of the Drainage Pipeline must be covered by thermal insulation materials to avoid generation of exterior condensate As shown in Figure 37 2 A Drainage outlet is located at both the left and right sides of the indoor unit After selecting one Drainage outlet the other outlet shall be blocked by rubber plug Bundle the ...

Page 31: ...g m 3 4 1 2 50 30 120g m 1 2 50 30 120g m Gas Pipe Liquid Pipe Max Pipe Length m Amount of Additional Refrigerant to be Filled For Extra Length of Pipe Note 1 5 The standard pipe length is m When the length L of the connecting pipe is less than or equals m 7 there is no need to add refrigerant If the connecting pipe is longer than m it is required to add 7 refrigerant In the above table the amount...

Page 32: ... the fitting pipes 4 Use sponge to wrap the connecting pipe and joint Then use plastic tape to bundle the sponge 5 Remove the bonnets of the liquid valve and the gas valve 6 Use an inner hexagon spanner to turn the spool of the liquid valve for 1 4 circle At the same time use a screwdriver to lift the spool Then there is discharge of gas 7 Refrigerant gas shall appear after the gas is discharged f...

Page 33: ...Pipe 1 To avoid generation of condensate on the connecting pipe and avoid leakage the big pipe and the small pipe of the connecting pipe must be covered by thermal insulation materials be bundled by adhesive tape and be isolated from air 2 The joint connecting to the indoor unit must be wrapped by thermal insulation material There shall be no gap between the connecting pipe joint and the wall of t...

Page 34: ...or the control wire should be metallic substance The wire controller could not be disassembled and the control wire be used for the wire controller should not be changed by users optionally the installation and maintenance should be carried out by the professional personnel 2 First select an installation position According to the size of the control wire of the wire controller leave a recess or a ...

Page 35: ... Figure 43 Surface Mounting of Cable Figure 44 Concealed mounting of Cable Figure 45 Schematic Diagram of Installation No Name 1 Wall Surface 2 Bottom Plate of Wire Controller 3 Screw M4X10 4 Panel of Wire Controller Caution 1 The communication distance between the main board and the wire controller is 8 meters 2 The wire controller shall not be installed in a place where there is water drop or la...

Page 36: ...the multiple twisted wires 4 Put the screw through the terminal of the multiple twisted wires and fix the terminal at the terminal board Warning If the power supply flexible line or the signal line of the equipment is damaged only use special flexible line to replace it 1 Before connecting lines read the voltages of the relevant parts on the nameplate Then carry out line connection according to th...

Page 37: ...Air conditioning unit with 3 phase power supply 1 Remove the front side panel of the outdoor unit 2 Attach rubber ring to the cable cross hole of the outdoor unit 3 Pass the cable though rubber ring 4 Connect the power cable to the terminal earthing marked L1 L2 L3 N 5 Use cable fastener to bundle and fix the cable Connect wire to the earthed terminal screw on the electric box Connection of Signal...

Page 38: ...iagram of Unit UThe section area of cables selected by users must not be smaller than the specifications shown diagram the signal wire between indoor and outdoor unit shall be installed in the shielded bushing Schematic Diagram of Unit Line Connection 37 FSOI 180B FSOI 240B FSOI 450B 3F FSOI 600B 3F ...

Page 39: ...dered 4 There is refrigerant leakage 5 The outdoor ambient temperature is lower than 5 6 Control line is abnormal 1 There is obstacle in front of the condenser Note After carrying out the check of the above items and taking relevant measures to solve the problems found but the air conditioning unit still does not function well please stop the operation of the unit immediately and contact the local...

Page 40: ...e if the line connection is in good condition Operating by the professional Check if there is any word displaying on the LCD of the wire controller after connecting the unit to power supply Note If there is any abnormal condition ask aftersales personnel to offer guidance 3 Maintenance at the End of the Operational Season 1 When the weather is clear operate the unit under fan mode for half a day s...

Page 41: ...sponding to standard external static pressure The parameters are subject to change with the improvement of products in which case the values on nameplate shall prevail 40 Appendix Air conditioner nominal working condition and working range Note Indoor side Outdoor side Test condition DB WB DB WB Nominal cooling 27 19 35 24 Nominal heating 20 7 6 Rated cooling 32 23 48 Low temp cooling 21 15 18 Rat...

Page 42: ...This product must not be disposed together with the domestic waste This product has to be disposed at an authorized place for recycling of electrical and electronic appliances 66129906999 ...