9. Troubleshooting
9.1 Indoor Unit Error Display
Operation lamp
Timer lamp
Display LED STATUS
☆
1 time
X
E0
Indoor unit EEPROM parameter error
☆
2 times
X
E1
Indoor / outdoor units communication error
☆
3 times
X
E2
Zero crossing signal detection error
☆
4 times
X
E3
Indoor fan speed has been out of control
☆
5 times
X
E4
Open circuit or short circuit of indoor room temperature T1
sensor
☆
6 times
X
E5
Open circuit or short circuit of evaporator coil temperature T2
sensor
☆
7 times
X
EC
Refrigerant Leakage Detection
☆
2 times
O
F1
Open circuit or short circuit of outdoor ambient T4 temperature
sensor
☆
3 times
O
F2
Open circuit or short circuit of condenser coil temperature T3
sensor
☆
4 times
O
F3
Open circuit or short circuit of compressor discharge T5
temperature sensor
☆
5 times
O
F4
Outdoor unit EEPROM parameter error
☆
6 times
O
F5
Outdoor fan speed has been out of control
☆
1 times
☆
P0
IPM malfunction or IGBT over-strong current protection
☆
2 times
☆
P1
Over voltage or over low voltage protection
☆
3 times
☆
P2
High temperature protection of compressor top diagnosis and
solution(Not used at these model)
☆
5 times
☆
P4
Inverter compressor drive error
O
(
light
)
X
(
off
)
☆(
flash
)
Summary of Contents for FSAI-Pro-122AE2
Page 11: ...11 5 Wiring Diagram 5 1 Indoor Unit FSOAI Pro 92AE2 FSAI Pro 122AE2 ...
Page 12: ...12 5 2 Outdoor Unit FSOAI Pro 92AE2 ...
Page 13: ...13 FSOAI Pro 122AE2 ...
Page 55: ...55 9 2 7 IPM malfunction or IGBT over strong current protection diagnosis and solution P0 ...
Page 56: ...56 9 2 8 Over voltage or too low voltage protection diagnosis and solution P1 ...
Page 57: ...57 9 2 9 High temperature protection of compressor top diagnosis and solution P2 ...
Page 58: ...58 9 2 10 Inverter compressor drive error diagnosis and solution P4 ...