![Fisher FSAI-Pro-122AE2 Service Manual Download Page 14](http://html.mh-extra.com/html/fisher/fsai-pro-122ae2/fsai-pro-122ae2_service-manual_2294425014.webp)
14
6 Installation Details
6.1 Wrench torque sheet for installation
Outside diameter
Torque
Additional tightening torque
mm
inch
N.cm
N.cm
Ф6.35
1/4
1500(153kgf.cm)
1600(163kgf.cm)
Ф9.52
3/8
2500(255kgf.cm)
2600(265kgf.cm)
Ф12.7
1/2
3500(357kgf.cm)
3600(367kgf.cm)
Ф15.9
5/8
4500(459kgf.cm)
4700(479kgf.cm)
6.2 Connecting the cables
The power cord of connect should be selected according to the following specifications sheet.
Rated capacity kBTU/h
Nominal cross-sectional area (mm²)
9k
2,5
12k
2,5
The cable size and the current of the fuse please chose according to the local rules..
Summary of Contents for FSAI-Pro-122AE2
Page 11: ...11 5 Wiring Diagram 5 1 Indoor Unit FSOAI Pro 92AE2 FSAI Pro 122AE2 ...
Page 12: ...12 5 2 Outdoor Unit FSOAI Pro 92AE2 ...
Page 13: ...13 FSOAI Pro 122AE2 ...
Page 55: ...55 9 2 7 IPM malfunction or IGBT over strong current protection diagnosis and solution P0 ...
Page 56: ...56 9 2 8 Over voltage or too low voltage protection diagnosis and solution P1 ...
Page 57: ...57 9 2 9 High temperature protection of compressor top diagnosis and solution P2 ...
Page 58: ...58 9 2 10 Inverter compressor drive error diagnosis and solution P4 ...