Fault Code 12
Lid Lock Switching Device Failure.
Remedy: Check that there are no short circuits in the lid lock circuit which may have
caused the failure in the sensor module. The resistance of the lid lock
should be between 50 and 100 ohms. If the circuit is correct, replace the
sensor module. (Refer to Section 6.36)
Fault Code 14
Sensor Module Fault.
Remedy: Replace the sensor module. (Refer to Section 6.36)
Fault Code 15
Sensor Module Fault.
Remedy: Replace the sensor module. (Refer to Section 6.36)
Fault Code 16
Airflow Restriction -
User Warning
.
Airflow restriction.
Remedy: (1) Check that the lint bucket is empty and the filter is clear.
(2) Ensure that the exhaust duct is not restricted, blocked or kinked,
preventing good airflow.
(3) Ensure that there is nothing inhibiting unrestricted airflow through the
heater housing, through the drum, lint filter, lint collector and through
the exhaust duct, and that the element has not shorted.
(4) Check that the voltage is not too high.
(5) Check for element shorts or low resistance, or that gas burner is
operating correctly.
(6) Replace the automatic thermostat. (Refer to Section 6.39)
(7) Replace the motor control module. (Refer to Section 6.35)