517762
15
7.1.2
Adjust Options Menu
In the Adjust Options menu it is possible to adjust the brightness of the LCD display screen as well
as selecting the appropriate language for the market the product is sold into. To scroll to the
appropriate screen use the
Options Up
or
Options Down
button.
Note: When the product leaves the factory the language should be preset, and there should
be no reason to adjust this. However when replacing the Sensor Module it will be
necessary to manually set the language.
To enter the Adjust Options menu press
Power
to turn the machine on. The adjacent screen
should now be displayed.
To access the Adjust Options Menu push the
Options Up
or
Options Down
button, and hold
for 2 seconds. The Adjust Options Menu will
then be displayed. One of the two screens as
shown below will be displayed.
To scroll through the different screens press the
Options Up
or
Options Down
buttons.
Language Selection
Press the
Adjust
button to change the selected
language. To lock the setting in press the
Home
button.
Display Brightness
To adjust the display brightness push the
Adjust
button, when the desired brightness has
been selected press the
Home
button to lock in
the setting.
7.1.3
Testing the Conductivity Contacts
Impedance Testing
It is possible to check the integrity of the conductivity contacts through diagnostics. Firstly enter
the Machine Status Screen as described in Section 7.1.1, and when in this mode, by touching
damp clothes or fingers across the conductivity contacts, the value adjacent to the word
Touch
will
increase. The minimum value is zero, this indicates an open circuit. The maximum value is 255.
No change in this value when touching the contacts, or conversely a high value when not touching
the contacts, would indicate a fault in this circuit.
Resistance Test
An alternative, but slightly less reliable method of testing the conductivity contacts, is to test the
circuit with a multimeter. When using this method the power to the dryer must be switched off.
Place one probe of the multimeter on each conductivity contact. The resistance should be
6. 2%.
To exit the diagnostic mode, press the
Power
button.