background image

SAFETY AND WARNINGS

1

 

Important safety instructions! 

 

Installation of this DishDrawer® requires basic mechanical and electrical skills.

 

Be sure to leave these Instructions with the Customer.

 

Installation must comply with your local building and electricity regulations.

 

At the completion of the DishDrawer® installation, the Installer must perform the Final Checklist.

 

Remove all packaging materials supplied with the DishDrawer®.

 

This DishDrawer® is manufactured for indoor use only.

 

Ensure all water connections are turned OFF. It is the responsibility of the plumber and 

 

electrician to ensure that each installation complies with all Codes and Regulations.

 

The DishDrawer® MUST be installed to allow for future removal from the enclosure if service is required.

 

The switched power outlet must be outside the DishDrawer® cavity, so that it is accessible after  

 installation.

 

Care should be taken when the appliance is installed or removed to reduce the likelihood of damage to 
the power supply cord.

 

If the DishDrawer® is to be relocated from one installation to another it must be kept upright to avoid 
damage from water spillage.

 

Make sure only new hoses are used for connection (supplied with DishDrawer®). Old hoses should not 
be reused.

 

Failure to install the DishDrawer® correctly could invalidate any warranty or liability claims.

 

If the product is installed in a motor vehicle, boat or similar mobile facility, you must bring the vehicle, 
boat or mobile facility containing the product to the service shop at your expense or pay the service 
technician’s travel to the location of the product.

DishDrawer®

Installation instructions

DD36S models

US CA

 

WARNING!

 

Electrical hazard

 

   

 

Before installing the DishDrawer®, remove the house fuse or open the circuit 

breaker.
If permanently connecting the DishDrawer®, be sure the power is isolated and 

the DishDrawer® unplugged. 
GROUNDING INSTRUCTIONS

This appliance must be grounded. In the event of a malfunction or breakdown, 

grounding will reduce the risk of electric shock by providing a path of least 

resistance for electric current. This appliance is equipped with a cord having 

an equipment-grounding conductor and a grounding plug. The plug must be 

plugged into an appropriate outlet that is installed and grounded in accordance 

with all local codes and ordinances. WARNING - Improper connection of the 

equipment-grounding conductor can result in a risk of electric shock. Check with 

a qualified electrician or service representative if you are in doubt as to whether 

the appliance is properly grounded.
If the DishDrawer is installed as a permanently connected appliance:

GROUNDING INSTRUCTIONS - This appliance must be connected to a grounded 

metal, permanent wiring system, or an equipment-groounding conductor must 

be run with the circuit conductors and connected to the equipment-grounding 

terminal or lead on the appliance.
Do not modify the power supply plug provided with the appliance - if it will not 

fit the outlet, have a proper outlet installed by a qualified electrician. Do not use 

an extension cord, adapter plug or multiple outlet box.

 

Failure to follow this advice may result in electrical shock or death.

Important!    

SAVE THESE INSTRUCTIONS

The models shown in this document may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, please visit our 
local website listed at the end of this document or contact your local Fisher & Paykel dealer.

 

WARNING!

 

Cut hazard

 

   

 

Take care - panel edges 

 are 

sharp.

 

Failure to use caution could 

 

result in injury or cuts.

95 lb

43 kg

 

WARNING!

 

 

Very Heavy

 

   

 

 

Do not attempt to lift this  

 product 

unassisted.

 

 

Lifting unassisted may  

 

cause serious injury.

(1,1)  -1- 599796A DD36S installA2 USCA.indd 19/2/10 11:32:01 AM

(1,1)  -1- 599796A DD36S installA2 USCA.indd 19/2/10 11:32:01 AM

Summary of Contents for DishDrawer DD36S

Page 1: ...solated and the DishDrawer unplugged GROUNDING INSTRUCTIONS This appliance must be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electric shock by providing a p...

Page 2: ...5 8 41 n a J height of front panel 18 470 18 470 2 K height of venting area at base of product 5 16 8 min 5 16 8 L height from top of handle to top of front panel 2 64 n a 1 Includesminimumpanelthickn...

Page 3: ...mm Power cord excl plug 29 750 mm 15 400 mm Left hand side Right hand side 2 x 4 Note Services can be located either side of DishDrawer Important Adjacentcabinetrymustnot extendabovecavitybase 110 12...

Page 4: ...ver Use copper conductors only Push back the drawer clips on both sides 13 16 30 mm Before refitting the drawer ensure the hoses are not twisted and the latches at the rear of each drawer runner are f...

Page 5: ...r side mounting brackets into their slots using a flat bladed screwdriver Ensure they re securely fitted before sliding product into cavity The mounting slots are in pairs one on each side diagonally...

Page 6: ...prise the plastic gray plug out of the trim moulding Replace the plastic gray plug back into the trim moulding and ensure the trimseal is facing forward Repeat for all four brackets Using a small Phil...

Page 7: ...in R 8 200 mm Air Break HIGHLOOP min 6 150 mm Ensure drain hose is routed straight to joiner Remove excess drain hose material if necessary Do not shorten the inlet hose Ensure drain hose is routed st...

Page 8: ...s Excessive water remaining above the filter plate after the rinse cycle Check for a kinked drain hose or blocked waste connection highloop not properly installed or drain hose not routed correctly No...

Reviews: