Fisher & Paykel DishDrawer DD24ST Series Installation Instructions Manual Download Page 1

Important!    

SAVE THESE INSTRUCTIONS

The models shown in this document may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, please go to our 

website www.fisherpaykel.com or contact your local Fisher & Paykel dealer.

SAFETY AND WARNINGS

1

DishDrawer®

Installation instructions

US CA

DD24ST models 

 

  Important safety instructions! 

  Installation of this DishDrawer® requires basic mechanical and electrical skills.

  Be sure to leave these Instructions with the Customer.

  Installation must comply with your local building and electricity regulations.

  At the completion of the DishDrawer® installation, the Installer must perform 

 

Final Check List.

  Remove all packaging materials supplied with the DishDrawer®.

  This DishDrawer® is manufactured for indoor use only.

  Ensure all water connections are turned OFF. It is the responsibility of the plumber and 

 

electrician to ensure that each installation complies with all Codes and Regulations.

  The DishDrawer® MUST be installed to allow for future removal from the enclosure if service is required.
 

The switched power outlet must be outside the DishDrawer® cavity so that it is accessible after   

 

installation.

  Care should be taken when the appliance is installed or removed to reduce the likelihood of damage to 

the power supply cord.

  If the DishDrawer® is to be relocated from one installation to another it must be kept upright to avoid 

damage from water spillage.

  Make sure only new hoses are used for connection (supplied with DishDrawer®). Old hoses should not 

be reused.

  Failure to install the DishDrawer® correctly could invalidate any warranty or liability claims.
  If the product is installed in a motor vehicle, boat or similar mobile facility, you must bring the vehicle, 

boat or mobile facility containing the product to the service shop at your expense or pay the service 
technician’s travel to the location of the product.

 

WARNING!

 

Electrical hazard

 

   

 

Before installing the DishDrawer®, remove the house fuse or open the circuit 

breaker.
If permanently connecting the DishDrawer®, be sure the power is isolated and 

the DishDrawer® unplugged. 
GROUNDING INSTRUCTIONS

This appliance must be grounded. In the event of a malfunction or breakdown, 

grounding will reduce the risk of electric shock by providing a path of least 

resistance for electric current. This appliance is equipped with a cord having 

an equipment-grounding conductor and a grounding plug. The plug must be 

plugged into an appropriate outlet that is installed and grounded in accordance 

with all local codes and ordinances. WARNING - Improper connection of the 

equipment-grounding conductor can result in a risk of electric shock. Check with 

a qualified electrician or service representative if you are in doubt as to whether 

the appliance is properly grounded.
If the DishDrawer is installed as a permanently connected appliance:

GROUNDING INSTRUCTIONS - This appliance must be connected to a grounded 

metal, permanent wiring system, or an equipment-groounding conductor must 

be run with the circuit conductors and connected to the equipment-grounding 

terminal or lead on the appliance.
Do not modify the power supply plug provided with the appliance - if it will not 

fit the outlet, have a proper outlet installed by a qualified electrician. Do not use 

an extension cord, adapter plug or multiple outlet box.

 

Failure to follow this advice may result in electrical shock or death.

 

WARNING!

 

Cut hazard

 

   

 

Take care - panel edges are sharp.

 

Failure to use caution could result in injury or cuts.

Summary of Contents for DishDrawer DD24ST Series

Page 1: ...claims If the product is installed in a motor vehicle boat or similar mobile facility you must bring the vehicle boat or mobile facility containing the product to the service shop at your expense or p...

Page 2: ...o countertop clearance can be increased to 3 mm Preferred position If adequate clearance services hole can be higher If hole is higher ensure drain hose s are routed straight into the waste connection...

Page 3: ...f drawer front panel excl curvature handle 18 18 18 18 H depth of curvature or handle 11 41 n a n a I height of drawer front 17 438 18 470 442 min 18 470 min J height of venting area at base of produc...

Page 4: ...ted and the latches at the rear of each drawer runner are facing forward Ensure the drawer clips on both sides are reset Ensure the drawer is now rotated clockwise back Remove knock out for cable clam...

Page 5: ...480mm CAVITY ONLY ATTACH CAVITY BRACKET SEE SEPARATE INSTRUCTION SHEET SUPPLIED WITH BRACKET 7...

Page 6: ...four side mounting brackets into their slots using a flat bladed screwdriver Ensure they re securely fitted before sliding product into cavity The mounting slots are in pairs one on each side diagonal...

Page 7: ...nsure hoses and cord are not kinked or twisted OPTIONAL 1 2 3 4 4 optional max 19 mm Open the drawer halfway Using a flat bladed screwdriver prize the plastic gray plug out of the trim moulding Replac...

Page 8: ...Supplied drain hose joiner 19 mm waste tee Air Break 37 950 mm Max height to top of Air Break countertop or wall mounted Ensure hoses are routed straight to joiner Remove excess hose material if nece...

Page 9: ...ned correctly Check water supply and drainage connection for leakage Spray arm Excessive water remaining above the filter plate after the rinse cycle Check for kinked drain hoses or blocked waste conn...