Fisher & Paykel DD24DC Installation Instructions Manual Download Page 1

DishDrawer®

Installation instructions

US CA

 

WARNING!

 

Electrical hazard

 

   

 

Before installing the DishDrawer®, remove the house fuse or open the circuit 
breaker.
If permanently connecting the DishDrawer®, be sure the power is isolated and 
the DishDrawer® unplugged. 
GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of a malfunction or breakdown, 
grounding will reduce the risk of electric shock by providing a path of least 
resistance for electric current. This appliance is equipped with a cord having 
an equipment-grounding conductor and a grounding plug. The plug must be 
plugged into an appropriate outlet that is installed and grounded in accordance 
with all local codes and ordinances. WARNING - Improper connection of the 
equipment-grounding conductor can result in a risk of electric shock. Check with 
a qualified electrician or service representative if you are in doubt as to whether 
the appliance is properly grounded.
If the DishDrawer is installed as a permanently connected appliance:
GROUNDING INSTRUCTIONS - This appliance must be connected to a grounded 
metal, permanent wiring system, or an equipment-groounding conductor must 
be run with the circuit conductors and connected to the equipment-grounding 
terminal or lead on the appliance.
Do not modify the power supply plug provided with the appliance - if it will not 
fit the outlet, have a proper outlet installed by a qualified electrician. Do not use 
an extension cord, adapter plug or multiple outlet box.

 

Failure to follow this advice may result in electrical shock or death.

DD24D models 

Important!    

SAVE THESE INSTRUCTIONS

The models shown in this document may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, please go to our 
website www.fisherpaykel.com or contact your local Fisher & Paykel dealer.

SAFETY AND WARNINGS

 

WARNING!

 

Cut hazard

 

   

 

Take care - panel edges are sharp.

 

Failure to use caution could result in injury or cuts.

1

 

Important safety instructions! 

 

Installation of this DishDrawer® requires basic mechanical and electrical skills.

 

Be sure to leave these Instructions with the Customer.

 

Installation must comply with your local building and electricity regulations.

 

At the completion of the DishDrawer® installation, the Installer must perform 

 

Final Check List.

 

Remove all packaging materials supplied with the DishDrawer®.

 

This DishDrawer® is manufactured for indoor use only.

 

Ensure all water connections are turned OFF. It is the responsibility of the plumber and 

 

electrician to ensure that each installation complies with all Codes and Regulations.

 

The DishDrawer® MUST be installed to allow for future removal from the enclosure if service is required.

 

The switched power outlet must be outside the DishDrawer® cavity so that it is accessible after   

 installation.

 

Care should be taken when the appliance is installed or removed to reduce the likelihood of damage to 
the power supply cord.

 

If the DishDrawer® is to be relocated from one installation to another it must be kept upright to avoid 
damage from water spillage.

 

Make sure only new hoses are used for connection (supplied with DishDrawer®). Old hoses should not 
be reused.

 

Failure to install the DishDrawer® correctly could invalidate any warranty or liability claims.

 

If the product is installed in a motor vehicle, boat or similar mobile facility, you must bring the vehicle, 
boat or mobile facility containing the product to the service shop at your expense or pay the service 
technician’s travel to the location of the product.

(1,1)  -1- 599618C DD24D install A2 USCA.indd 15/4/09 10:01:39 AM

(1,1)  -1- 599618C DD24D install A2 USCA.indd 15/4/09 10:01:39 AM

Summary of Contents for DD24DC

Page 1: ...d specification availability in your country please go to our website www fisherpaykel com or contact your local Fisher Paykel dealer SAFETY AND WARNINGS WARNING Cut hazard Take care panel edges are sharp Failure to use caution could result in injury or cuts 1 Importantsafetyinstructions Installation of this DishDrawer requires basic mechanical and electrical skills Be sure to leave these Instruct...

Page 2: ...5 11 16 398 15 11 16 398 min L height of lower drawer front 14 356 14 356 12 311 5 min M height of installation bracket slots on top of chassis 1 16 2 1 16 2 1 16 2 N height of drawer fronts 29 9 16 751 30 1 16 764 28 717 5 min Chassis heights include bracket slots less the Toekick Panel thickness Minimum Panel thickness using the supplied screws is 3 8 9 mm Note for Prefinished Flat door models h...

Page 3: ...s hole can be higher to clear toekick space If hole is higher ensure drain hose s are routed straight into the waste connection Water Connection Recommended HOT Maximum 140 F 60 C Supplied hose to suit 3 8 9 mm male compression fitting 110 120 VAC max 15 A Note Services can be located either side of DishDrawer max ø 1 38 mm min 7 7 8 200 mm 3 8 10 mm max 17 11 16 450 mm If no side partition use a ...

Page 4: ...ar of each drawer runner are facing forward Ensure the drawer clips on both sides are reset Ensure the drawer is now rotated clockwise back Remove knock out for cable clamp Fit suitable cable clamp for the conduit and terminate the wiring as shown Use copper conductors only 5 7 8 150 mm C D Remove Power supply B OPTIONALLY HARD WIRING THE PRODUCT 6 2 2 1 599618C DD24D install A2 USCA indd 15 4 09 ...

Page 5: ... 3 optional optional x2 Ensure hoses and cord are not kinked or twisted B 30 mm 1 2 3 4 5 5 5 150 mm Ensure the drawer is removed and then rotated counter clockwise to prevent kinked hoses 5 7 8 150 mm A OR Loosen feet only and take care when pushing the product into the cavity that you do not bend the feet If top mounting brackets are being used ensure they re securely fitted before sliding produ...

Page 6: ...oth sides are reset Ensure the drawer is now rotated clockwise back B The product has three pairs of mounting brackets a pair of optional brackets on the top C and two pairs of formed brackets in the side of the chassis A B Use at least two out of the three pairs to secure the product Ensure the sound insulation is repositioned correctly Where the toekick meets the bottom of the tub is the cut off...

Page 7: ...tee Air Break 37 3 8 950 mm Max height to top of Air Break countertop or wall mounted Fit supplied washer Ensure hoses are routed straight to joiner Remove excess hose material if necessary DishDrawer and Standpipe Ø 1 1 2 38 mm 29 34 750 882 5 mm min R 8 200 mm Waste Disposal optional B Fit supplied washer 180o 180o 180o Ensure hoses are routed straight to joiner Remove excess hose material if ne...

Page 8: ...d drainage connection for leakage Repeat for each drawer Spray arm Excessive water remaining above the filter plate after the rinse cycle Check for kinked drain hoses or blocked waste connection high loop not properly installed or drain hoses not routed correctly No water supply shows on display models with LCD only Check water is connected turned on and the spray arm s are correctly fitted and fr...