background image

Important!    

SAVE THESE INSTRUCTIONS

The models shown in this document may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, please visit our 

local website listed at the end of this document or contact your local Fisher & Paykel dealer.

SAFETY AND WARNINGS

  Important safety precautions! 

  Particular attention shall be given to the relevant requirements regarding ventilation.
  Please make this information available to the person installing the appliance as it could reduce your 

installation costs.

  This appliance is to be installed and connected to the electricity and gas supply only by an authorised 

person.

  Installation must comply with your local building and local gas authority codes and electricity 

regulations.

  Failure to install the appliance correctly could invalidate any warranty or liability claims.
  These appliances are registered in: (New Zealand) at www.ess.govt.nz and (Australia) with SAI Global 

at www.saiglobal.com.

  This gas appliance is suitable for connection to natural gas only. If in doubt, refer to the local gas 

network operator or gas supplier to confirm gas type at installation site.

 
 

 

WARNING!

  

    Cut hazard

 

Take care - panel edges are sharp.

 

Failure to use caution could result in injury or cuts.

 

WARNING!

  

 

 

Electrical shock hazard

 

Disconnect appliance from main power supply before continuing.

 

 

Failure to do so could result in electrical shock or death.

Before you install the appliance, please make sure that

 

  the local distribution conditions (nature of gas and pressure) and the adjustment of the appliance 

are compatible.  For adjustment conditions for this appliance, see ‘Gas rate summary’

  a suitable disconnection switch is incorporated in the permanent wiring, mounted and positioned to 

comply with the local wiring rules and regulations.  A means of disconnection with at least a 3 mm 
air gap contact separation in all poles must be incorporated into the fixed wiring in accordance with 
the wiring rules, unless the local wiring rules allow for alternative means

  the appliance is connected to a 220V - 240V 50Hz (10 A) power supply only and earthed via the 

power supply cable

  there is a power outlet within reach of the power supply cable (900 mm from the centre rear of the 

product).  This must be accessible after installation.  The power supply cable should not touch any 
metal parts

  if the power supply cable is damaged, it is replaced only by the special cable: Part no. 531953 - Flex 

Terminal Block Assy NZ/AU, obtainable from authorised Fisher & Paykel Service Agents

  the supply connection point (gas shut-off valve) is accessible after installation
  the benchtop is made of a heat resistant material
  the installation complies with all the requirements of Australian and New Zealand Gas Installation 

Standards (AS5601, NZS5261), including that the product has to be installed so that the surface 
temperature of any nearby combustible surface will not exceed 65 

O

C above ambient. See  3 

‘Clearance Dimensions’.

 
 

When you install the appliance 

  We 

do not recommend

 you flush mount or seal this appliance into the bench with silicone or glue. 

Doing so will make future servicing difficult. Fisher & Paykel will not be liable for any costs associated 
with removing or replacing a sealed-in appliance, nor for repairing any damage that may be incurred 
by doing this.  

  Seal exposed bare edges of the cutout with an oil-based paint or moisture-proof polyurethane to 

prevent possible moisture creeping between the cooktop trim and the benchtop.

  We 

do not recommend

 the use of a down-draught extractor fan with the appliance, as it may distort 

the flame pattern, causing uneven heating and reduced cooking performance.

  Where this appliance is installed in marine craft or in caravans, it shall not be used as a space heater.
  No combustible material or products should be placed on this appliance at any time.
  Do not spray aerosols in the vicinity of this appliance while it is in operation.
  If, after following the instructions given, the appliance cannot be adjusted to perform correctly, 

please refer to the Service & Warranty book for warranty details and your nearest Authorised Service 
Centre, Customer Care, or contact us through our website: www.fisherpaykel.com.

1

IZONA CookSurface

Installation instructions

CG903ML & CG903MLD models

NZ AU

Summary of Contents for CG903ML

Page 1: ...ative means the appliance is connected to a 220V 240V 50Hz 10 A power supply only and earthed via the power supply cable there is a power outlet within reach of the power supply cable 900 mm from the...

Page 2: ...ed on adjacent walls 150 150 E minimum clearance from glass surface to rangehood any other overhead exhaust fan downward facing combustible surface re resistant surface 650 800 650 500 650 800 650 500...

Page 3: ...Z AU Injector orifice mm Nominal rating MJ h Injector orifice mm Nominal rating MJ h Injector orifice mm Nominal rating MJ h NG 1 0 kPa SMALL MEDIUM WOK NG NG NG CG903ML CG903MLD 1 09Y 7 2 1 15Y 8 0 1...

Page 4: ...er radius of routered recess max 2 max 2 N height of routered recess 5 5 M K L M N J 1 1 2 2 x4 20 50mm 5 mm 3 min 150 O C rated TO REMOVE PRODUCT 1 2 B A D C F E WARNING We do not recommend flush mou...

Page 5: ...ave direct unrestricted ventilation to the room where the CookSurface is installed Do not ventilate the base area to an external area that can be at different air pressure to that of the burners You m...

Page 6: ...rners 13 14 11 12 GAS ON A GAS ON 20 50mm 1 2 50 mm 1 2 x4 A Fresh air from outside cabinetry Fresh air from outside cabinetry Refit existing screw to secure into basepan view from below For benchtops...

Page 7: ...egulator set to the correct working pressure Have you placed the supplied duplicate data plate on an adjacent surface Is the CookSurface earthed Check that the power supply cable is NOT touching the C...

Reviews: