Fisher & Paykel CG604DX1 Installation Instructions Manual Download Page 1

HK SG

590633B      11.14

CG604DX1 & CG905DX1

models

Gas cooktop

INSTALLATION INSTRUCTIONS

Summary of Contents for CG604DX1

Page 1: ...HK SG 590633B 11 14 CG604DX1 CG905DX1 models Gas cooktop INSTALLATION INSTRUCTIONS...

Page 2: ...PG but are convertible to Town gas Singapore and Town gas Hong Kong If in doubt refer to the local gas network operator or gas supplier to confirm gas type at installation site Do not modify this appl...

Page 3: ...cable is damaged it is replaced only by the special cable Part no 534906 TRMNL BLOCK FLEX ASSY HITEMP GOG UK obtainable from authorised Fisher Paykel Service Agents the supply connection point gas shu...

Page 4: ...lamping brackets 4 and screws 4 3 GAS RATE SUMMARY All appliances are factory set for LPG or Town Gas CG604DX CG905DX SEMI RAPID SEMI RAPID SEMI RAPID SEMI RAPID MINI WOK RAPID WOK AUX AUX Gas Elbow 1...

Page 5: ...2 30 4 86 LPG G30 2 9 kPa 29 mbar 0 55 1 1 0 76 2 36 0 94 3 33 0 94 3 33 0 73 0 73 0 50 4 86 BURNER GAS TYPE AUX SEMI RAPID RAPID MINI WOK WOK Jet size mm Nominal rating kW Jet size mm Nominal rating...

Page 6: ...ht of chassis below top of bench 59 59 e width of chassis 555 856 f depth of chassis 486 486 G overall width of cutout 560 865 H overall depth of cutout 490 490 I corner radius of cutout max 10 max 10...

Page 7: ...surface 650 800 650 500 650 800 650 500 f minimum clearance below top of benchtop to combustible surface Fisher Paykel oven or nearest non combustible surface 70 65 70 65 G minimum distance from right...

Page 8: ...2 75kPa w thetwosemi rapidburne operatingathighestsettin Washer Washer Arrow x4 Recycle responsibly Model may vary from illustrations shown 500 mm 50 mm 500 mm 25 mm 25 mm 500 mm min S A R min A F S R...

Page 9: ...uirements Thehosemustnotbekinked subjectedtoabrasionorpermanentlydeformed Thehosemustnotbenearorincontactwithanyhotsurfaces e g baseofmetalhotlplate flue orchassisofunderbenchovenetc Ifconnectingthega...

Page 10: ...emustnotbekinked subjectedtoabrasionorpermanentlydeformed Thehosemustnotbenearorincontactwithanyhotsurfaces e g baseofmetalhotlplate flue orchassisofunderbenchovenetc Ifconnectingthegaswithaflexibleho...

Page 11: ...LPG or Town Gas matches the type of gas at the site of installation Have you used the fibre washer supplied Have you leak tested all connections Is the appliance set to the correct working pressure Ha...

Page 12: ...HK SG 590633B 11 14 CG604DX1 CG905DX1...

Page 13: ...1...

Page 14: ...3mm 220V 240V 50Hz 10A 900mm 534906 TRMNL BLOCK FLEX HITEMP GOG 1...

Page 15: ...2 1 1 1 4 4 3 CG604DX CG905DX 1 1 2 BSP 1 1...

Page 16: ...33 1 10 2 30 2 30 4 86 G30 2 9 kPa 29 mbar 0 55 1 1 0 76 2 36 0 94 3 33 0 94 3 33 0 73 0 73 0 50 4 86 mm kW mm kW mm kW mm kW mm kW G110 0 8 kPa 8 mbar 1 50 1 1 2 07 2 36 3 20 3 33 3 50 3 33 1 30 2 50...

Page 17: ...4 mm CG604DX1 CG905DX1 a 64 64 b 600 900 c 530 530 d 59 59 e 555 856 f 486 486 G 560 865 H 490 490 I 10 10 J 30 30 K 21 21 A K D B E C G F J H I...

Page 18: ...H D F G 5 mm CG604DX1 CG905DX1 a 130 130 b 115 115 c 160 45 160 45 d 150 150 e 650 800 650 500 650 800 650 500 f 70 65 70 65 G 250 250 H 800 850 800 850 I 600 600 900mm 800 850mm H 250mm G ISO A I B C...

Page 19: ...retofitthesupplied washerandregulator Adjusttoobtainatestpoint pressureof1kPawiththetwo semi rapidburnersoperatingat highestsetting LPGModels Makesuretofitthesuppli washerandtestpointada Makesurethesu...

Page 20: ...ssureof1kPawithallthe burnersoperatingat highestsetting Ensurethehoseislongenoughtoallowforremovalofcooktopforservicing Makesuretheconnectorislocatedasshowninstep5CLEARANCEDIMENSIONS Thehoseassemblymu...

Page 21: ...ooktopforservicing Makesuretheconnectorislocatedasshowninstep3CLEARANCEDIMENSIONS ThehoseassemblymustbeAS NZS1869ClassBorDcertified withanRp ISO7 1 femaleth Thehoseassemblymustbeasshortaspracticablean...

Page 22: ...17 www fisherpaykel com...

Page 23: ......

Page 24: ......

Reviews: