background image

Gas Cooktop

CG604DX & CG905DX

models

GB IE IN

INSTALLATION INSTRUCTIONS

590877A      06.15

www.fisherpaykel.com

Summary of Contents for CG604DX

Page 1: ...Gas Cooktop CG604DX CG905DX models GB IE IN INSTALLATION INSTRUCTIONS 590877A 06 15 www fisherpaykel com...

Page 2: ......

Page 3: ...l injury or damage and could invalidate any warranty or liability claims This gas appliance is suitable for connection only to the gas type for which it was set at the factory as declared on the appli...

Page 4: ...anent ventilation through a free area of at least 100 cm2 will be required For rooms with a volume between 5 m3 and 10 m3 permanent ventilation through a free area of at least 50 cm2 will be required...

Page 5: ...le should not touch any metal parts If the power supply cable is damaged it is replaced only by the special cable Part no 534994 KIT SPARES TRMNL BLK FLEX 11 obtainable from authorised Fisher Paykel S...

Page 6: ...ssemblies should be BS 699 1 certified Seal exposed bare edges of the cutout with an oil based paint or moisture proof polyurethane to prevent possible moisture creeping between the cooktop trim and t...

Page 7: ...1 04 0 70 4 53 3894 LPG 29 mbar Nominal rating g h 0 56 1 23 90 g h 1074 0 75 2 31 169 g h 2020 0 95 3 64 262 g h 3129 0 69 0 69 0 51 4 45 320 g h 3825 Nominal pressure with at least one large burner...

Page 8: ...rs dials and pan supports 64 64 B Overall width of product 600 900 C Overall depth of product 530 530 D Height of chassis below top of bench 59 59 E Width of chassis 555 856 F Depth of chassis 486 486...

Page 9: ...resistant surface 650 800 650 500 650 800 650 500 F Minimum clearance below top of benchtop to Combustible surface Fisher paykel oven or nearest non combustible surface 70 65 70 65 G Minimum distance...

Page 10: ...longenoughtoallowforremovalofcooktopforservicing Makesuretheconnectorislocatedasshowninstep3CLEARANCEDIMENSIONS ThehoseassemblymustbeAS NZS1869ClassBorDcertified withanRp ISO7 1 femalet Thehoseassembl...

Page 11: ...test point pressure of 20 mbar with all the burners operating at highest setting Ensure the hose is long enough to allow for removal of cooktop for servicing Make sure the connector is located as show...

Page 12: ...eflamewithoutanyyellowtipping Ifanyabnormalityisevident checkthatthecomponentsoftheburnerassemblyarelocatedproperly Ifproperoperationcannotbeobtained contactyournearestF PAuthorisedServiceCentre Theco...

Page 13: ...mbination Check for a well defined blue flame without any yellow tipping If any abnormality is evident check that the components of the burner assembly are located properly If proper operation cannot...

Page 14: ...correct working pressure Have you affixed the supplied duplicate data plate label on an adjacent surface accessible to the customer Is the cooktop earthed Check that the power supply cord is NOT touch...

Page 15: ...13...

Page 16: ...tions in this booklet apply to the specific products and models described at the date of issue Under our policy of continuous product improvement these specifications may change at any time You should...