321144
16
2
SERVICING REQUIREMENTS
2.1
Specialised Service Tools
For the servicing of this product, specialised tools are needed.
2.1.1
Static Strap
To be used as ESD protection when replacing any of the electronic boards.
2.1.2
Interface Light Pen Mk 2
Used in conjunction with a diagnostic programme on a laptop computer to retrieve and download data from
the electronic power/control module.
2.2
Health & Safety
2.2.1
Good Work Practices
1.
Take care while removing all plastic components, especially when cold.
2.
Leave the product clean and tidy when service work is completed.
3.
Extreme heat in cabinets will cause plastic deterioration or distortion and thermal fuses in the
evaporator to go open circuit (be careful with heat guns).
2.2.2
Environmental Health And Safety
When servicing products, consider health and safety issues and requirements that must be adhered to at all
times. Specific safety issues are:
1.
Electrical safety.
2.
Electrostatic discharge.
3.
Mixing of foam insulation.
4.
Vapours while brazing.
5.
Reclaiming of refrigerant.
2.2.3
Good Practice And Safety
1.
Take care when removing or servicing all electrical components to avoid electrical shock or short
circuit conditions.
2.
Take care when removing plastic components at low temperatures as breakages can occur with these
components.
3.
Extreme heating of plastic components can cause distortion of those parts being heated.
4.
Avoid overheating temperature sensitive devices such as the element thermal fuses and cabinet
sensors.
5.
Avoid using solvents and citrus-based cleaners on all plastic parts. We advise only warm soapy water
be used.
CAUTION – R600a REFRIGERANT (ISOBUTANE)
Some models of refrigerators contain R600a refrigerant within the sealed in system. This refrigerant is
flammable.
All care must be taken when servicing these products. Vent well before brazing. Avoid any
open flames or ignition source.
Summary of Contents for 635 Active Smart
Page 1: ...321144 Service Manual 635 680 790 900 Active Smart Refrigerator Freezer R134a R600a Systems...
Page 2: ...321144 2...
Page 96: ...321144 96 Photo 12 22 5...
Page 100: ...321144 100 Diagram 12 25...
Page 108: ...321144 108 13 11 Embraco Compressor Fitted With External Overload Diagram 13 11...
Page 114: ...321144 114 14 2 Non Ice Water Models Wiring Diagram...
Page 116: ...321144 116 14 4 Ice Water Models Wiring Diagram...
Page 117: ...321144 117 14 5 900 Models Power Control Module Wiring Connections Reciprocating Compressor...
Page 118: ...321144 118 14 6 900 Models Wiring Diagram Reciprocating Compressor...
Page 119: ...321144 119 14 7 900 Models Power Control Module Wiring Connections VC Compressor...
Page 120: ...321144 120 14 8 900 Models Wiring Diagram VC Compressor...
Page 121: ...321144 121 14 9 B Model Wiring Route Diagram 14 9...
Page 122: ...321144 122 14 10 T Model Wiring Route Diagram 14 10...
Page 145: ......