background image

1

44710-0121 instructions. A4 (W 210mm x H 297mm) 

Page 1 

FISH MATE

® 

5

00

/

1000

Pond  Pump•  Instructions 

Ci) 

www.pet-mate.com  (() (936) 760 4333 

IMPORTANT SAFETY 

INSTRUCTIONS 

WARNING - To guard 

against injury or death, 

basic safety precautions 

should be observed, 

including the following: 

READ AND FOLLOW 

ALL SAFETY 

INSTRUCTIONS 

•  Register  your  purchase  on-line

at 

www.pet-mate.com/us 

(see

guarantee below).

•  All  electrical  work  must  be carried

out by a competent electrician.

•  Check that the voltage label on the

motor (G) (see Fig. 1) conforms with

your supply voltage.

•  The  pump  MUST  be  wired  into  a 

ground  fault  circuit  interrupter

(G.F.C.I.)  maximum  30mA  and  a 

3 AMP (maximum) fuse.

•  Connection  to  the  power  supply

should  be  made  through  a  double

pole  switched  enclosure  with

minimum  1/8"  (3mm)  contact

separation in all poles.

•  This appliance must be earthed. It is

essential  that  all  connections  are

securely  made  using  the  following

code:

Black - Live 

White - Common 

Green - Ground 

•  Do not carry or pull the pump using

the supply cord.

• Disconnect electrical supply from all

appliances  in  the  pond  including

pumps  and  filters  before  contact

with the pond water or pump.

•  Maximum  operation  depth  is  5ft

(1.5m).

•  Closely  supervise  children  when

near to pond or pond equipment.

•  Use pump  only for ponds  - do not

use  pump  in  connection  with

swimming pools, showers, etc.

•  Use  conduit  approved  by  your

electricity authority to protect supply

cord where damage from gardening

equipment,  children  and  animals

may occur.

•  Discard  pump  if  motor  (G)  shows

visual  defects  (e.g.  cracks  or

swelling).

•  The  supply  cord  of  this  appliance

cannot  be  replaced;  if  the  cord  is

damaged  the  appliance  should  be

discarded.

•  Do not allow the pump to run dry. 
•  Do not operate the pump in freezing

conditions.  Remove,  disassemble

and  dry  pump  if  there  is  a  risk  of

pump being frozen.

•  This  pump  is  provided  with  a 

thermal  cut-out  switch  that

temporarily switches off the pump in

case of overheating. The pump may

restart when it has cooled.

SAVE THESE 

INSTRUCTIONS 

®---E([Q 

®------E[J 

IMPORTANT - READ BEFORE USE 

1.  PUMP INSTALLATION 

For convenience the pump should be positioned within reach 

from  the  side  of  the  pond  on  a  solid platform  (e.g. paving 

slabs) approximately 10"  (250mm) below the pond surface. 

The pump should be at least 8"  (200mm) below water level 

to avoid problems of freezing and low water levels in summer 

and no more than 60" (1500mm) deep. 

Only use pump if completely immersed in water. 

A.  Waterfall/Filter Only 

For use with a pond filter you will often get improved results 

with the pump sited at the opposite end of  the pond to the 

filter return. 

The  pump  may  be  connected  to  a  waterfall  or  filter  using 

1/2"  (12mm),  3/4"  (19mm)  or  1"  (25mm)  bore  hose.  Fit 

suitable outlet adapter 

(K) 

and flow valve (L) into pump outlet 

(J).  Insert  adapter  (P) 

if 

required  and  connect  hose  to 

required outlet (see Fig 2c). Insert plug (Q) in unused outlet 

and adjust flow using the flow control knob 

(M). 

B.  Fountain (and Waterfall/Filter) 

Insert fountain components as shown in Fig. 2a (conventional 

fountain) / 2b (bell fountain). If required tubes (R) and (T) may 

be shortened with a hacksaw. Also fountain (W) may be fitted 

directly to flow valve  (N). For plume fountain do  not fit any 

parts to tube 

(T). 

If required, connect waterfall/filter with hose 

to outlet (0) or (P). Alternatively, use blanking plug (Q). The 

Fountain  heads  (V)  may  be  unscrewed  anticlockwise  for 

cleaning. Adjust fountain heighl/width using the flow control 

(M) turning clockwise for increased height. If using the bell 

fountain  you  will  also  need  to  manually  adjust  the  gap 

between  parts 

(W) 

and  (X)  for  the  required  effect.  (Try

starting with approximately 1/16" (1mm) gap.) 

2.  MAINTENANCE / FAULT FINDING - IMPORTANT SAFETY 

INSTRUCTIONS 

•  Disconnect  electrical  supply  from  pump  before 

removing from pond or contacting pond water. 

•  Do not carry or pull the pump by the cable.

A.  ROUTINE MAINTENANCE OR WHEN FLOW FROM YOUR 

PUMP  IS  NOTICEABLY  REDUCED  OR  FOUNTAIN

DISPLAY HAS DETERIORATED: 

i)  Remove  strainer  cover  (A)  as  shown  by  arrows 

G) 

and 

® 

in Fig. 1. Clean strainer covers 

(A) 

and (H) using a stiff 

brush. 

ii)  Check  and  remove  any  obstruction  to  inlet  on  impeller 

cover (B). 

iii)  Remove and clean fountain head in water with a brush. 

iv)  Reassemble, taking care to align cut out in top of cover (A) 

with grooves (I). 

IMPORTANT 

If flow is still poor check: 

•  Flow control (M) is correctly set. 

•  No blockage or kinks in outlet hose. 

B. ONCE  A  YEAR  OR  IF  FLOW  IS  STOPPED  (CHECK 

POWER SUPPLY FIRST!): 

Completely  disassemble  pump  to  the  component  parts 

shown in Fig. 1 as follows: 

i)  Disconnect all items fitted to pump outlet (J). 

ii)  Remove strainer cover (A) as shown in Fig. 1. 

iii)  Remove  impeller  cover  (B)  by  rotating  anticlockwise.  If 

required, pliers can be used as shown in Fig. 3. 

iv)  Carefully pull out pump impeller assembly (E) then (F). 

v)  After cleaning of all components: 

•  Check  cable  and  pump  body  (G)  for  any  damage  or 

deterioration. If pump body (G) is damaged,  remove rear 

strainer  cover  (H)  and  check  internal  motor  for  signs  of 

visual  defects  (e.g.  cracks  or  swelling).  Discard  pump  if 

suspected faulty. 

•  Check for wear of impeller (E) on shaft (F) and condition of 

seal (C), rubber bushes (D1) and (D2). Replace with new 

parts  using  the  appropriate  FISH  MATE  service  kit  as 

required. 

Carefully reassemble as follows: 

vi)  Locate shaft (F) into rubber bush (D2) inside pump body (G). 

vii) 

Carefully and slowly slide impeller assembly (E) on to shaft 

(F) to avoid damage from the powerful magnet. 

viii) 

Lubricate rubber bush (D1) by immersing in water and then 

push halfway on to the end of shaft (F). Align impeller cover 

(B)  before  pushing  on  fully  and  rotating  clockwise  into 

position. 

ix)  Refit  front  cover  (A)  taking  care  to  align  cut  out  with 

grooves (I). 

Pet Mate Ltd. guarantees your product for a period of 3 years from the date of purchase, subject to the registration of your purchase 

details on our website 

www.pet-mate.com/us 

within 14 days of purchase. (If you do not have access to a computer, please send details 

of your purchase with copy of receipt along with your name and address.) In the event of a fault developing contact Pet Mate customer 

services for a returns authorisation number. The guarantee is limited to any defect arising due to faulty materials or manufacture. Any 

defective item will be repaired or replaced free of charge at the manufacturer's  discretion,  provided that the defect has not been caused 

by neglect, misuse or normal wear and tear. The guarantee excludes moving parts and claims arising from frost, accidental damage or 

loss of fish.  Your statutory rights are not affected. 

Reviews: