7 | Technical data
FISCHER Mess- und Regeltechnik GmbH
98
BA_EN_DE90
7.5 Digital interfaces
USB interface
USB On The Go
2.0
Data rate
12 Mbit/s (Full Speed)
Port
Micro USB typee B
Communication
Host/Device mode
Modbus RTU interface
interface
RS 485
Report
Modbus RTU
Modbus specification
Application Protocol Specification
V1.1b3 (April 26, 2012)
Address
1 … 255
Baud rate
2400 … 115200 Baud
Parity
Even, uneven, parity
Stopbits
1…2
7.6 Auxiliary energy
NOTICE! A CE-conform mains adapter with a slow 200 mA fuse only may
be used in the power supply circuit for ATEX devices.
Nominal voltage
24 V AC/DC
Admissible operating voltage U
b
19.2 … 28.8 V AC/DC
Power consumption
Type 2W (VA)
Max. 3W (VA)
7.7 Operating conditions
Standard
ATEX
Ambient temperature range
-20 … +70 °C
-20 … +60 °C
Medium temperature range
-20 … +70 °C
-20 … +60 °C
Storage temperature range
-20 … +70 °C
-20 … +70 °C
Protection
IP65
IP65
ATEX
EN IEC 60079-0:2018
EN 60079-15:2010
EN 60079-31
EMC
EN 60730-1:2016
EN 61326-1:2013
EN 61326-2-3:2013
RoHS
EN IEC 63000:2018
7.8 Display
Display
Full graphic LC display
Resolution
128 x 64 Pixel
Backlight
RGB
Measured value display
6 digits
Summary of Contents for PRO-LINE DE90