FISCHER Mess- und Regeltechnik GmbH
Technical data | 7
BA_EN_DE90
95
7 Technical data
7.1 General
Type designation
DE90
Pressure type
Differential pressure
Measurement principle
Piezo-resistive
Reference conditions (acc. to IEC 61298-1)
Temperature
+15 … +25 °C
Relative humidity
45 … 75 %
Air pressure
86 … 106 kPa
860 … 1060 mbar
Installation position
vertical
7.2 Input variables
Asymmetric measuring ranges:
Measuring range (Channel 1 2)
Overload
Bursting
pressure
Sensor
type
-20 … +80 Pa
750 mbar
1 bar
A
0 … 25 Pa
750 mbar
1 bar
A
0 … 40 Pa
750 mbar
1 bar
A
0 … 60 Pa
750 mbar
1 bar
A
0 … 1 mbar
0 … 100 Pa
750 mbar
1 bar
A
0 … 1.6 mbar
0 … 160 Pa
750 mbar
1 bar
A
0 … 2.5 mbar
0 … 250 Pa
750 mbar
1 bar
A
0 … 4 mbar
0 … 400 Pa
100 mbar
200 mbar
B
*
0 … 6 mbar
0 … 600 Pa
100 mbar
200 mbar
B
*
0 … 10 mbar
0 … 1 kPa
100 mbar
200 mbar
B
*
0 … 16 mbar
0 … 1.6 kPa
400 mbar
800 mbar
B
0 … 25 mbar
0 … 2.5 kPa
400 mbar
800 mbar
B
0 … 40 mbar
0 … 4 kPa
400 mbar
800 mbar
B
0 … 60 mbar
0 … 6 kPa
1 bar
2 bar
B
0 … 100 mbar
0 … 10 kPa
1 bar
2 bar
B
0 … 160 mbar
0 … 16 kPa
2.5 bar
5 bar
B
0 … 250 mbar
0 … 25 kPa
2.5 bar
5 bar
B
*)
Sensors can be delivered with a higher overload and bursting pressure capab-
ility with these measuring ranges (see order code/special aspects).
Symmetric measuring ranges:
Measuring range (Channel 1 2)
Overload
Bursting
pressure
Sensor
-25 … +25 Pa
750 mbar
1 bar
A
-40 … +40 Pa
750 mbar
1 bar
A
-60 … +60 Pa
750 mbar
1 bar
A
-1 … +1 mbar
-100 … +100 Pa
750 mbar
1 bar
A
-1.6 … +1.6 mbar
-160 … +160 Pa
750 mbar
1 bar
A
-2.5 … +2.5 mbar
-250 … +250 Pa
100 mbar
200 mbar
B
*
-4 … +4 mbar
-400 … +400 Pa
100 mbar
200 mbar
B
*
-6 … +6 mbar
-600 …. +600 Pa
100 mbar
200 mbar
B
*
-10 … +10 mbar
-1 … +1 kPa
100 mbar
200 mbar
B
*
Summary of Contents for PRO-LINE DE90