FISCHER Mess- und Regeltechnik GmbH
Operation | 5
BA_EN_DE90
79
5.5.4.1 Analog output 1 type
Directory: \...\...\An.output 1 type
Level: 3
\...\...\An.output 1 type
1
2 3
4
Current 0...20 mA
Current 4...20 mA
Voltage 0...10 V
Voltage 2...10 V
S
R
U
R
R
Fig. 113:
Analog output 1 type
The signals can be set for output 1:
Current signals
Voltage signals
0 … 20 mA
0 … 10 V
4 … 20 mA
2 … 10 V
1 … 5 V
5.5.4.2 Analog output 1 assignment
Directory: \Configuration\Analog output\An.output 1 assignmt
Level: 3
An.output 1 assignmnt
1
2 3
4
Channel 1
Channel 2
Back
S
E
U
R
Channel 3
R
Fig. 114:
Analog output 1 assignment
The assignment of the analogue outputs to the channels can be set freely. This
menu item is not required for a device with just one channel.