Safety guidelines 

1.1 

General Information 

This  operating  manual  contains  instruc-
tions fundamental to the  installation, op-
eration  and  maintenance  of  the  device 
that must be observed unconditionally. It 

must  be  read  by  the  assembler,  operator  and  the 
specialized  personnel  in  charge  of  the  instrument  
before it is installed and put into operation. This op-
erating  manual  must  always  be  accessible  at  the 
place of installation.  

The subsequent sections on general safety instruc-
tions  1.2  -  1.7  as  well  as  the  following  special  in-
structions  ranging  from  intended  use  to disposal  2-
10  contain  important  safety  instructions  the  non-
observance of which can cause danger to persons, 
animal and physical objects.  

1.2 

Personnel Qualification 

The  instrument  may  only  be  installed  and  commis-
sioned by specialized personnel familiar with the in-
stallation,  commissioning  and  operation  of  this 
product. 

Specialized personnel are persons who can assess 
the  work  they  have  been  assigned  and  recognize 
potential dangers by virtue of their specialized train-

ing, their skills and experience and their knowledge 
of the pertinent standards. 

For explosion-proof models the specialized person-
nel  must  have  received  special  training  or  instruc-
tion  or  be  authorized  to  work  with  explosion-proof 
instruments in explosion hazard areas.  

1.3 

Risks due to Non-Observance of Safe-
ty Instructions 

Non-observance of these safety instructions, the in-
tended use of the device or the limit values given in 
the  technical  specifications  can  be  hazardous  or 
cause  harm  to  persons,  the  environment  or  the 
plant itself. The supplier of the equipment will not be 
liable for damage claims if this should happen.  

1.4 

Safety Instructions for the Operating 
Company and the Operator 

The  safety  instructions  governing  correct  operation 
of  the instrument  must  be  observed.  The  operating 
company must make them available to the  installa-
tion,  maintenance,  inspection  and  operating  per-
sonnel. Dangers arising from electrical components, 
energy  discharged  by  the  medium,  escaping  medi-
um and incorrect installation of the instrument must 
be  eliminated.  The  particulars  can  be 
found  in  the  respective  regulations 
such  as  DIN,  EN,  explosion  hazard, 

 

Data Sheet and Operating Manual 

 

ME01 

Digital manometer 

 

ME01 ## # 87 # HL R#### 

 

 

Gas explosion protection zone 2 

Summary of Contents for Me01 Series

Page 1: ...nd operation of this product Specialized personnel are persons who can assess the work they have been assigned and recognize potential dangers by virtue of their specialized train ing their skills and...

Page 2: ...e operating company s internal work operating and safety guidelines must be observed The operating company is responsible for ensuring that all required maintenance inspection and instal lation work i...

Page 3: ...afe operation of the in strument the supply circuit must satisfy the requirements for zone 2 category 3 and the locally applicable regulations and guidelines for the installation and operation of elec...

Page 4: ...nst impacts It may only be transported in packaging specifically intended for transport 8 Service All defective or faulty devices should be sent direct ly to our repair department We would ask you to...

Page 5: ...y Only CE compliant power supply units with a slow 200 mA fuse may be used Rated voltage 24V DC Allowed operating voltage Ub 15 30 V DC inner effective capacity Ci max 270nF effective inner inductivit...

Page 6: ...12 Dimensional drawings all dimensions in mm unless otherwise specified M16 x 1 5 Manometer connection port G1 2 nach DIN EN 837 SW22...

Page 7: ...urement accuracy Characteristic curve dev Relative pressure 1 0 M Characteristic curve dev Absolute pressure 1 0 S Discharge port Connection ports with external thread G B bottom Stainless steel 8 7 E...

Page 8: ...change without notice Changements techniques sous r serve Fischer Mess und Regeltechnik GmbH Bielefelder Str 37a D 32107 Bad Salzuflen Tel 49 5222 9740 Fax 49 5222 7170 eMail info fischermesstechnik...

Reviews: