MAINTENANCE CLEANING (ultrasonic cleaning) - FO1, FO2 &FO4

 

Put your connector under running tap water until everything is globally cleaned 

 

Remove the sleeve holder, manually unscrew it for FO1 or use tweezers for FO2, FO4 and FOH and repeat the  

 

  cleaning with the IBC

TM

 Brand cleaner

 

Put the connector & the sleeve holder in the ultrasonic bath for ~1 minute. 

 

Dry the contacts 

&

 connector by spraying canned air on it. 

 

Dry the sleeve holder by spraying canned air on it

 

Reassemble the sleeve holder

 

Slightly grease the plug sealing plan to recover full sealing capabilities*

 

Ultrasonic bath 

 

Recommended bath composition: Isopropyl alcohol

<