![FISCHER EA16 Series Operating Manual Download Page 22](http://html1.mh-extra.com/html/fischer/ea16-series/ea16-series_operating-manual_2294185022.webp)
5 | Parameterization
FISCHER Mess- und Regeltechnik GmbH
22 / 88
BA_EN_EA16
5.4.1 Menu: History [Level 2]
Menu path: Main menu/History/
History
1st level
Data logger
Fig. 27:
Menu: History
The recorded measured values are presented in a chart in this menu. There is a
wide range of functions available to analyse the data.
5.4.1.1 Graphic display
The measured values are saved on the micro SD card accordingto the setting in
the menu
. This saved data can be presented graphically in
the History menu. Generated data is used to explain the graphic display.
max
avg
min
50.0
25.0
0
-25.0
-50
35.8
61
24.7
12803
-24h
mbar
Unit
Measuring range
Cursor
Time stamp
Zoom level
Selector switch
Presentation
Selector switch channel
Channel 1
Channel 2
Channel 3
Channel 4
01.02.2018 - 16:04:25
Selected channel
Fig. 28:
Graphic display
The following functions are available in the graphic display
•
Presentation or measurements
Using the presentation tiles
max
,
avg
and
min
the presentation type of the
measurements can be changed.
•
Channel selection
The channel is selected with the channel tile on the bottom edge of the
screen. The measuring range belonging to the channel and the unit are
shown on the right edge of the screen. The selected channel is shown in a
white colour.
•
Cursor
The cursor is used to select a specific point in time. The measurements of
the channels at this time are shown on the associated channel tile.
Fig. 29:
Circular menu
•
Circular menu
If the screen is touched at any point, the circular menu with other functions
appears.