5.3.7 Sensors and Switches for Operating Surveillance
Terminal block for remote control cable
with fuses and power relais
F1 fuse 15 A for DC wiring
F2 fuse 25 A for starter relay
Ks power relais for Starter
K2 power relais for Glow plugs
K3 power relais for Fuel pump
Fig. 5.3.6-12: Terminal block
K2
Ks
K3
F1 F2
Thermo-switch at cylinder head
The thermo-switch at the cylinder head serves
to monitor the generator temperature. All
thermo-switches for the generators from
Panda 6.000 upward are two-pole (earthed),
so called "openers". This means the contacts
are open in normal cases and close only when
the limits have been exceeded.
Fig. 5.3.7-1: Thermo-switch at Cylinder Head
Thermo-switch at watercooled exhaust
elbow
This thermo switch is located at the water-
cooled exhaust elbow and serves to
monitor the freshwater circulation system.
It takes a measurement at the warmest
spot, since the combustion gases are
guided from the cylinder head to the
exhaust elbow.
Fig. 5.3.7-2: Thermo-switch at Watercooled Exhaust Elbow