The Panda Generator
Seite/Page 50 - Kaptitel/Chapter 5: The Panda Generator
9.12.14
5.3.3 Components of Cooling System (Freshwater)
IN/OUT generator housing
The raw water cooles the coil in the generator
housing.
Fig. 5.3.2-7: In/Out Generator Housing
Cooling water injector nozzle
The injection point for the marine generator
water-cooled exhaust system is located at the
exhaust connection pieces. The exhaust con-
nections must be regularly checked for signs of
corrosion.
Fig. 5.3.2-8: Injetion Nozzles for Cooling Water
Filler neck
The cooling water filler necks situated at the
water-cooled manifold are only used, when the
generator is initially started. Since the genera-
tor is normally already filled with cooling water,
these components are only by the user, if
repairs are to be carried out. Topping up with
cooling water may only carried out at the exter-
nal cooling water compensation tank. Note that
the water level in the cooling water compensa-
tion tank is only 20 % of the volume in a cold
state.
Fig. 5.3.3-1: Cooling Water Filler Neck