Tables
14.2.13
Panda_4800i PMS_eng.R04 - Kapitel/Chapter 8: Tables Seite/Page 123
8. Tables
8.1
Troubleshooting
DIESEL MOTOR FAILS TO START
Cause
Solution
Starter battery switched „OFF“.
Check position of battery switch and switch „ON“ (if
installed).
Starter battery voltage insufficient (battery too weak).
Inspect battery terminals and cables for a good electrical
connection (Inspect against corrosion, tattered wires,
etc.).
Starting current disrupted.
During the normal starting process, the battery voltage
drops to 11V with a fully charged battery. If the voltage
does not drop during starting, the electrical connection is
faulty. If the battery voltage drops lower than 11V, then
the battery has been discharged.
STARTER IS TURNING MOTOR, BUT FAILS TO START
Cause
Solution
Fuel inlet solenoid valve not opening.
Check wire connections and circuitry to solenoid valve.
(ref. DC wiring diagram: Relay K2, Fuse)
Fuel pump not working.
Check fuel-filter and pump: clean if necessary.
Lack of fuel.
Check fuel supply.
Glow-plugs not working correctly.
Check glow plugs and heating time.
Too much air in fuel lines.
Test fuel system for leakage. Bleed air from fuel system
Fuel-filter blocked.
Replace fuel filter.
MOTOR RUNS IRREGULARLY
Cause
Solution
Faulty centrifugal injector governor.
Have the centrifugal governor inspected by a Farymann-
Service technician.
Too much air in fuel lines.
Bleed air from fuel system.
MOTOR DOES ACHIEVE ENOUGH SPEED DURING STARTING PROCESS
Cause
Solution
Starter battery voltage insufficient.
Check battery.
Damaged bearing(s) piston (seized).
Repairs need to be carried out by Farymann-Service.
(refer to Farymann motor-manual)
Summary of Contents for Panda 4800i PMS
Page 36: ...Seite Page 36 Panda_5000i_PVMV N_Book_eng R02 14 2 13 Leere Seite Intentionally blank Basics ...
Page 130: ...Seite Page 130 Panda_4800i PMS_eng R04 14 2 13 Leere Seite Intentionally blank Tables ...
Page 148: ...Page 148 Chapter 2 General operation 14 2 13 Intentionally left blank General operation ...
Page 156: ...Page 156 Chapter 3 Installation 14 2 13 Intentionally left blank Installation ...
Page 158: ...Page 158 Chapter 4 Maintenance 14 2 13 Intentionally left blank Maintenance ...
Page 164: ...Page 164 Chapter 6 Annex 14 2 13 Intentionally left blank Annex ...