Maintenance Instructions
14.2.13
Panda_4800i PMS_eng.R04 - Kapitel/Chapter 6: Maintenance Instructions Seite/Page 109
6.12.1 Checking the water separator in the fuel supply
Fig. 6.12.1-1: Fuel filter with water separator
The pre-filter with water separator has a cock at its lower sur-
face, with this cock the downward sunk water can be dis-
charged.
This is simply possible, water is heavier due to its density than
the Diesel.
This pre-filter does not belong to the scope of supply.
6.13 Replace the air filter element
Fig. 6.13-1: Air suction housing
Pull the holder out to change the element.
Fig. 6.13-2: Air filter element
Open the air suction holder by loosen the two quick release
fasteners.
If no change of the cooling water level can be determined, the generator is started for 5 minutes. Afterwards repeat
the de-aeration two - three times.
It is meaningful to repeat the de-aeration procedure also after some days again to guarantee that in the system