![Fischer Panda Panda 25i PMS User Manual Download Page 132](http://html1.mh-extra.com/html/fischer-panda/panda-25i-pms/panda-25i-pms_user-manual_2294283132.webp)
Maintenance Instructions
Seite/Page 132 - Kaptitel/Chapter 7: Maintenance Instructions
20.7.15
7.20.3 Alternative replacement of the air filter at housing with snap fasteners
Fig. 7.20.3-1: Air suction housing
1. Open the combustion air housing by loosening the closure
on the right side of the housing.
01. Closure
Fig. 7.20.3-2: Air suction housing
2. Open the combustion air housing by loosening the closure
on the left side of the housing.
01. Closure
Fig. 7.20.3-3: Air suction housing
3. Open the air housing by pulling the cover.
4. Lift out the air filter element of the cover of the air filter
housing.
01. Air filter
5. Replace cover in reverse procedure.
Sample picture
01
01
01