Installation Instructions
Page 48
AGT 6000 PVMV-N 12V_24V - Chapter B: Installation Instructions
B.5 Voltage Control System - see VCS datasheet
The VCS control is used for the adjustment of the number of revolutions of the engine and thus
the voltage of the generator. It belongs to the accessories and is externally attached.
Fig. B.5-1: Electronic Voltage Control VCS
ATTENTION!
The cable for the measuring voltage must be attached directly at the bat-
tery, and may not attached to the output of the electric rectifier.
By the voltage drop between generator and battery the accurate voltage can
only recieved direct at the battery. A false link can lead to damage the battery!
06
03
04
01
05
07
09
02
08
01. Measuring voltage (+) (24V)
02. Measuring voltage (-) (24V)
03. Actuator (+)
04. Actuator (-)
05. Battery voltage supply (+)
06. Battery voltage supply (-)
07. Stop-line (regulates the actuator back at shut-off
device)
08. Terminal shunt-measurement 60mV DC (-)
09. Terminal shunt-measurement 60mV DC (+)