The Panda Generator
Page 40 AGT 6000 PVMV-N 12V_24V - Chapter A: The Panda Generator
A.4.2 Daily routine checks before starting
1. Oil Level Control (ideal level: MAX).
AtTTENTION! OIL PRESSURE CONTROL!
True, the diesel motor automatically switches off when there is a lack of oil, but it is very damaging for the motor, if
the oil level drops to the lowest limit. Air can be sucked in suddenly when the boat rocks in heavy seas, if the oil
level is at a minimum. This affects the grease in the bearings. It is therefore necessary to check the oil level daily
before initially running the generator. The oil level must be topped up to the maximum level, if the level drops
below the mark between maximum und minimum levels.
You should change the oil, regardless off the ambient temperature. Table E.2.1, “Engine oil,” on
Page 92. Engine oil amounts Table E.4, “Technical Data Engine,” on Page 99.
2. State of Cooling Water.
The external compensation tank should be filled up to a maximum of in a cold state. It is very important that large
expansion area remains above the cooling water level.
3. Check all Hose Connections and Hose Clamps are Leakage.
Leaks at hose connections must be immediately repaired, especially the seawater impeller pump. It is certainly
possible that the seawater impeller pump will produce leaks, depending upon the situation. (This can be caused
by sand particles in the seawater etc.) In this case, immediately exchange the pump, because the dripping water
will be sprayed by the belt pulley into the sound insulated casing and can quickly cause corrosion.
4. Check all electrical Lead Terminal Contacts are Firm.
This is especially the case with the temperature switch contacts, which automatically switch off the generator in
case of faults. There is only safety if these systems are regularly checked, and these systems will protect the gen-
erator, when there is a fault.
5. Check the Motor and Generator Mounting Screws are Tight.
The mounting screws must be checked regularly to ensure the generator is safe. A visual check of these screws
must be made, when the oil level is checked.
6. Switch the Land Electricity/Generator Switch to Zero before Starting or Switch Off all the Con-
sumers.
The generator should only be started when all the consumers have been switched off. The excitation of the gene-
rator will be suppressed, if the generator is switched off with consumers connected, left for a while, or switched on
with extra load, thus reducing the residual magnetism necessary for excitation of the generator to a minimum. In
certain circumstances, this can lead to the generator being re-excitated by means of a DC source. If the generator
does not excitate itself when starting, then excitation by means of DC must be carried out again.
7. Check the Automatic Controls Functions and Oil Pressure.
Removing a cable end from the monitoring switch carries out this control test. The generator should then automat-
ically switch off. Please adhere to the inspection timetable (see Checklist in the appendix).
Summary of Contents for AGT 6000 PVMV-N
Page 1: ...Panda AGT 6000 PVMV N Super silent technology 24V 6kW Fischer Panda GmbH ...
Page 6: ......
Page 10: ...8 Socket wrench set Hexagon wrench keys ...
Page 92: ...Generator Failure Page 90 AGT 6000 PVMV N 12V_24V Chapter D Generator Failure ...
Page 100: ...Appendix Page 98 AGT 6000 PVMV N 12V_24V Chapter E Appendix ...
Page 102: ...Page 100 AGT 6000 PVMV N 12V_24V Chapter E E 6 Capsule Measurements ...
Page 106: ...VCS AGT U I Page 104 Chapter A VCS AGT U I VCS AGT UI_eng fm Fischer Panda Datasheet blank ...