The Panda Generator
Seite 22 Panda 8000 PMS Operation Manual.V02 - Kapitel A: The Panda Generator - Details of functional units
9.1.08
Stop solenoid for engine stop
Some models are additional equipped
with a stop solenoid. The generator is
stopped by the co-operation of the stop
solenoid immediately after switching off.
The adjustment of the stop solenoid must
always be checked, in order to be sure
that the stop lever operate freely and is
not placed under pre-stress.
Fig. A.2.3-7: Stop Solenoid
A.2.4 Components of Combustion Air
Air Suction Openings at the Sound
Insulated Capsule
The sound cover for the marine generator
is normally provided at the lower surface
with drillings, through which the combu-
stion air can inflow.
It must be consistently paid attention that
the generator is installed in such a way
that no water can enter from below in
close proximity to these air openings.
(Minimum distance 150 mm).
Fig. A.2.4-1: Combustion air intake
Drillings for combustion air at the
sound insulated capsule
Drillings at the lower surface of the sound
cover serve the admission of fresh air for
the entrance. It must be safe that no raw
water or other water can come into this
range of openings. If air is sucked in
through these openings, water can pene-
trate also into the sound cover.
Fig. A.2.4-2: Drillings for Combustion Air