The Panda Generator
9.1.08
Panda 8000 PMS Operation Manual.V02 - Kapitel A: The Panda Generator - Details of functional units Seite 17
Ventilation pipe
The ventilation pipe at the water-cooled
exhaust manifold leads to the external
expansion tank. This pipe only serves as a
ventilation pipe, if both pipes are to be
connected to the external expansion tank
(ventilation pipe and intake pipe).
Fig. A.2.2-3: Ventilation pipe
Hose connection pieces for the
external expansion tank
The external expansion tank is connected
by two hose connections. The connecting
pieces showed here serves as constant
ventilation for the water-cooling system.
In case the external expansion tank is
connected with two hoses, the system will
ventilate itself. In this case, additional ven-
tilation is only necessary when the gene-
rator is initially filled, or if the cooling water
is not circulating.
Fig. A.2.2-4: External Expansion Tank
Heat exchanger
The internal freshwater circulation system
is separated from the Raw water circula-
tion system by the heat exchanger. This
means the Raw water circulation system
does not come into contact with the gene-
rator components. The Raw water is fed
directly to the exhaust connection at the
heat exchanger outlet.
Fig. A.2.2-5: Heat Exchanger