Maintenance Instructions
22.3.11
Panda PMS 8.000 NE - 42 NE Manual.R05 - Kapitel/Chapter 6: Maintenance Instructions Seite/Page 107
Fig. 6.8-2: Grease lubricated backend bearing
Grease lubricated backend bearing with cooling disc.
Sample Picture
6.8.1 Exchange of grease lubricated bearing
STOP!
Only special trained persons are allowed to do this
maintenance!
Warning!: Automatic start
DANGER FOR LIFE! - Inappropriate handling can lead to health
damages and death.
The battery bank must always be disconnected (first negative pole, then
positive pole), while working at the generator or at the generators’ electrical
system, so that the generator can not be started unintentionally.
6.8.1.1 Demounting the cooling disc (if existent)
Fig. 6.8.1.1-1: Demounting the cooling disc
To demount the cooling disc, detach the cooling discs’ holding
nut and take off the disc.
Sample Picture
6.8.1.2 Demounting the backend bearing