General operation
30.10.12
Chapter 10: General operation - Page 141
.
Warning!: Automatic start-up
The autostart function will remain active even after the
controller is switched off and on again with the On/Off button.
To deactivate the autostart function, the flag in the EEPROM
must be reset with "Disable" as described above.
The autostart function of the Panda iControl2 is now ready. While the autostart function is active, you can manually
start and stop the generator with the Start/Stop button, as well.
Note: Manual start in autostart mode
If the generator is manually started up and stopped while in
automatic start mode, it will switch to stand-by mode for safety
reasons.
If necessary, the autostart mode must be reactivated.
10.2.7 Resetting the service interval ("Service")
Note
As the indication of operating hours remaining until the next
service interval can be reset at any time, it serves only as an
orientation guide. The service intervals shall be implemented
using the actual operating hours and shall be properly
documented in the service log of the generator.
Note:
With the dynamic operation hours the service interval can be
raised up to 30% (200h max.). Make sure that the dynamic
operation hours are not reset accidently between the service
interval.
In the set-up menu, select the menu item "Service" and confirm as usual, using the Start/Stop button. This
will open the screen with the service information discussed above, supplemented with the instruction to
actuate the Start/Stop button to reset the service interval.
Fig. 10.2.7-1: Resetting the time until the next service
Resetting the time until the next service
By actuating the Start/Stop button again, you can reset the
service interval to the original interval. The service interval for
each generator type is stored in the software.
The controller is switched off after resetting the service
interval. After restart, the new value will be displayed in the
service screen.
10.2.8 Priming the fuel system ("Prime Fuel")
To prime the fuel system, the Panda iControl2 offers the option of separately activating the fuel pump. In the set-up
menu, select the menu item "Prime fuel" and confirm your selection using the Start/Stop button.
Fig. 10.2.8-1: Set-up menu
Actuating the Start/Stop button again will switch on the fuel
pump for a duration of max. 30 seconds. After that, the fuel
pump will shut off automatically.
Naturally, you can also switch off the fuel pump manually.
For this purpose, confirm the menu item "Prime fuel"
again, and switch off the fuel pump using the Start/
Stop button.
Summary of Contents for 5000i PVK-U
Page 36: ...Seite Page 36 Panda_5000i_PVMV N_Book_eng R02 30 10 12 Leere Seite Intentionally blank Basics...
Page 48: ...The Panda Generator Seite Page 48 Kaptitel Chapter 4 The Panda Generator 30 10 12...
Page 126: ...Generator Tables Seite Page 126 Kaptitel Chapter 8 Generator Tables 30 10 12...
Page 150: ...Page 150 Chapter 11 Installation 30 10 12 Intentionally left blank Installation...
Page 152: ...Page 152 Chapter 12 Maintenance 30 10 12 Intentionally left blank Maintenance...
Page 158: ...Page 158 Chapter 14 Annex 30 10 12 Intentionally left blank Annex...