General operation
Page 136 - Chapter 10: General operation
30.10.12
Fig. 10.1.3.6-1: Default display screen in autostart mode
The display status field reading "AUTOSTART" indicates that
the autostart function is active, or, if it reads "STANDBY", this
means that the autostart function was deactivated.
.
Warning!: Automatic start-up
The autostart function will remain active even after the
controller is switched off and on again with the On/Off button.
To deactivate the autostart function, the flag in the EEPROM
must be reset with "Disable". See “Activating/deactivating the
autostart function ("Autostart")” on Page 139.
Note: Manual start in autostart mode
If the generator is manually started up and stopped while in
automatic start-up mode, it will switch to stand-by mode for
safety reasons.
If necessary, the autostart mode must be reactivated.
10.2 Other operating functions
10.2.1 Set-up menu
In the set-up menu, a series of parameters can be modified directly using the control panel. To access the set-up
menu, you have to actuate the cursor-down button immediately after switching on the controller with the On/Off
button and while the start screen with panda bear is still being displayed. This will open a menu with the following
sub-items:
Fig. 10.2.1-1: Set-up menu
Menu item
Settings range for
backlight 1
Setting the brightness value for the standard backlighting to 0-9
backlight 2
Setting the brightness value for the dimmed backlighting to 0-9
Dimtime (dimming time)
Time until the display switches to dimmed mode, 0-225s, 0= function deactivated
Config
Password protected area for Fischer Panda associates and Fischer Panda service points
Network ID
Settings for the network ID of the panel
Save & Exit
Saving the values and exiting the set-up menu
Autostart
Activating and deactivating the automatic start-up function
Service
Resetting the "Operating hours to service" indication
Prime fuel
Activation of the fuel pump to prime the generator fuel system
Degree C/F
Switches the display between °C and °F
Summary of Contents for 5000i PVK-U
Page 36: ...Seite Page 36 Panda_5000i_PVMV N_Book_eng R02 30 10 12 Leere Seite Intentionally blank Basics...
Page 48: ...The Panda Generator Seite Page 48 Kaptitel Chapter 4 The Panda Generator 30 10 12...
Page 126: ...Generator Tables Seite Page 126 Kaptitel Chapter 8 Generator Tables 30 10 12...
Page 150: ...Page 150 Chapter 11 Installation 30 10 12 Intentionally left blank Installation...
Page 152: ...Page 152 Chapter 12 Maintenance 30 10 12 Intentionally left blank Maintenance...
Page 158: ...Page 158 Chapter 14 Annex 30 10 12 Intentionally left blank Annex...