7.6.2.1 Optional fuel filter with sight glass
Fig. 7.6.2.1-1: Fuel filter
The filter change depends on the fuels’ degree of pollution,
but should be executed every 300 operating hours at the
latest.
01. Fuel filter housing
02. Fuel filter element
03. Sight glass
Fig. 7.6.2.1-2: Fuel filter
Unscrew the housing from its mount (left hand rotation).
Fig. 7.6.2.1-3: Fuel filter
Unscrew the filter element from the mount (left hand
rotation).