General operation
8.10.14
Kapitel/Chapter 2: General operation - Seite/Page 195
Fig. 2.4.6-6: Goodbye screen prior to shutting down
Then, the controller is shut down.
Fig. 2.4.6-7: Default display screen in autostart mode
After switching the controller back on, the display status
field reading "AUTOSTART" indicates that the autostart
function is active, or, if it reads "STANDBY", this means
that the autostart function was deactivated:
.
Warning!: Automatic start-up
The autostart function will remain active even after the
controller is switched off and on again with the On/Off
button. To deactivate the autostart function, the flag in
the EEPROM must be reset with "Disable" as described
above.
The autostart function of the Panda iControl2 is now ready. While the autostart function is active, you can manually
start and stop the generator with the Start/Stop button, as well.
Note: Manual start in autostart mode
If the generator is manually started up and stopped while
in automatic start mode, it will switch to stand-by mode
for safety reasons.
If necessary, the autostart mode must be reactivated.
2.4.7 Resetting the service interval ("Service")
Note
As the indication of operating hours remaining until the
next service interval can be reset at any time, it serves
only as an orientation guide. The service intervals shall
be implemented using the actual operating hours and
shall be properly documented in the service log of the
generator.
Note:
With the dynamic operation hours the service interval
can be raised up to 30% (200h max.). Make sure that the
dynamic operation hours are not reset accidently
between the service interval.
In the set-up menu, select the menu item "Service" and confirm as usual, using the Start/Stop button. This will open
the screen with the service information discussed above, supplemented with the instruction to actuate the Start/Stop
button to reset the service interval.
Summary of Contents for 45i pms
Page 3: ...8 10 14 Kapitel Chapter A Seite Page 3...
Page 4: ...Seite Page 4 Kaptitel Chapter A 8 10 14...
Page 12: ...Seite Page 12 Kaptitel Chapter 1 8 10 14...
Page 148: ...Generator Failure Seite Page 148 Kaptitel Chapter 8 Generator Failure 8 10 14...
Page 160: ...Tables Seite Page 160 Kaptitel Chapter 9 Tables 8 10 14...
Page 176: ...Inverter Panda PMGi 45 Seite Page 176 Kaptitel Chapter 10 Inverter Panda PMGi 45 8 10 14...
Page 212: ...Seite Page 212 Kapitel Chapter 6 Annex 8 10 14 Leere Seite Intentionally blank Annex...