![Fischer Panda 15000i PMS Manual Download Page 121](http://html1.mh-extra.com/html/fischer-panda/15000i-pms/15000i-pms_manual_2294291121.webp)
Inverter Panda PMGi
4.5.16
Kapitel/Chapter 10: Inverter Panda PMGi - Seite/Page 121
10.7.2 Settings in the Victron VE Configure II Software - Inverter
Fig. 10.7.2-1: Settings in the Victron VE configure II Software
10.7.2.1 Assist current boost factor
To reduce the action of the power inverter on the iGenerator, the Assist current boost factor must be reduced from
2.0 to1.3. Wrong settings will cause bad rpm control of the generator.
Summary of Contents for 15000i PMS
Page 10: ...Seite Page 10 Kapitel Chapter 2 4 5 16 Leere Seite Intentionally blank...
Page 70: ...Installation Instructions Seite Page 70 Kaptitel Chapter 5 Installation Instructions 4 5 16...
Page 112: ...Tables Seite Page 112 Kaptitel Chapter 9 Tables 4 5 16...
Page 176: ...Seite Page 176 Kapitel Chapter 16 Annex 4 5 16 Leere Seite Intentionally blank Annex...