Basics
Seite/Page 34 - Kaptitel/Chapter 3: Basics
10.6.16
Attention!
Cover alternator apertures.
Cleaning fluids and preservatives must not enter the
alternator. Risk of destroying the alternator.
• Clean engine as per manufacturer's instructions.
• Spray engine parts and V-belt disks with preservative.
• Clean air filter housing and spray with preservative (metal housing only).
• Spray preservative on intake and exhaust side of exhaust turbocharger (where applicable) and reconnect the lines.
• Remove valve cover and spray inside of valve cover, valve stems, springs, rocker, etc. with preservative oil.
• Remove injection nozzle and coat cylinder surface with preservative oil. Hold stop lever in zero delivery position
and crank engine manually several times. Refit injection nozzles with new seals (at an operation hour of min. 100
hours after the last change). Observe torque values.
• Spray radiator cover and tank cover or radiator cover on expansion tank lightly with preservative oil and refit.
• Close off intake and exhaust apertures (e.g. with tape or end caps).
Note:
For storage for more than 12 months, the preservation
measures shall be checked annually and supplemented
as necessary.
Attention!
Before recommissioning, remove preservatives and
protective measures.
3.8.4.2 Measures for removing surface protection after extended downtimes /
recommissioning (over 6 months):
• Check battery charge status and recharge if necessary. Observe instructions of the battery manufacturer.
• Check cooling water anti-freeze level and cooling water level and refill as necessary.
• Drain engine oil. Replace oil filter and oil as per the specification.
• Remove preservatives from the engine with petroleum spirit.
• Degrease V-belt disks and mount V-belt according to instructions. Check V-belt tension!
• If applicable, open turbocharger oil pressure line and fill clean engine oil into channel.
• Hold engine stop lever in zero delivery position and crank engine manually several times.
• Clean air filter housing with petroleum spirit, check air filter and replace if necessary.
• Remove covers from exhaust aperture and intake apertures.
• Connect battery. Close battery main switch.
• Hold stop lever on generator motor in neutral position and crank starter for approx. 10 seconds. Then, pause for 10
seconds. Repeat this procedure 2 times.
• Perform visual check of the generator similar to initial commissioning and start up generator.
Note:
Fischer Panda recommends:
After extended downtimes, a full 150 h inspection as per the
inspection list should be performed.
Summary of Contents for 10000x
Page 10: ...Seite Page 10 Kapitel Chapter 2 10 6 16 Leere Seite Intentionally blank...
Page 96: ...Installation Instructions Seite Page 96 Kaptitel Chapter 5 Installation Instructions 10 6 16...
Page 148: ...Seite Page 148 Kapitel Chapter 9 Appendix 10 6 16 Leere Seite Intentionally blank Appendix...
Page 149: ...Panda_xControl_eng R01 5 10 6 16 Panda xControl Manual...
Page 189: ...Panda xControl 10 6 16 Kapitel Chapter 11 Panda xControl Seite Page 189...