![Fischer Panda 10000/9 Manual Download Page 170](http://html1.mh-extra.com/html/fischer-panda/10000-9/10000-9_manual_2294272170.webp)
Maintenance Instructions
Seite/Page 170 - Kaptitel/Chapter 9: Maintenance Instructions
9.12.14
9.25 Replacing the Injection Nozzles
NOTE:Representative procedure
The described procedure is representative for Fischer Panda
generators. The original location of the item must be taken
from the generator description of this manual. All
replacements and repairs should be done by a trained
person.
ATTENTION!
Ensure that the generator cannot be started up
accidentally. Remove battery main switch.
Fig. 9.25-1: Injection nozzles
Injection lines
Figures similar!
1. Remove cable ties from the injection lines.
Fig. 9.25-2: Injection nozzles
2. Loosen the pipe clamps (1) using a PH2 phillips
screwdriver.
1