Maintenance Instructions
Seite/Page 110 - Kaptitel/Chapter 9: Maintenance Instructions
9.12.14
9.6
Oil Change Intervals
The first oil change is to be accomplished after a period of operation from 35 to 50 hours. Afterwards the oil is to be
changed after 150 hours. For this, the oil SAE30 for temperatures over 20°C and SAE20 for temperatures between
5°C and 20°C is to be used. At temperatures under 5°C oil of the viscosity SAE10W or 10W-30 is prescribed.
For filling quantity, see „Technical Data“ at page 107.
9.7
Checking oil-level
You require:
paper towels / cloth for the oil dipstick
The generator must be placed at level.
• with vehicular generators: Place the vehicle on a levelled surface.
• with PSC generators: Place the generator on a levelled surface.
• with marine generators: Measure the oil-level when the ship is not lop-sided.
Run the generator for about 10 minutes to ensure that the engine is warm. Wait for 3 minutes, so the oil can flow
back into the oil pan.
Caution: Burn hazard!
Generator and coolant can be hot during and after
operating.
Wear personal protective equipment. (Gloves, protective
goggles, protective clothing and safety shoes)
• Assure generator against accidental start.
• Open the generator casing.
• Pull the oil dipstick out of the check rail.
• Clean oil dipstick.
• Put the oil dipstick back into the check rail and wait for 10 seconds.
• Pull the oil dipstick out of the check rail and read off the oil-level at the lower end of the stick.
Fig. 9.7-1: Oil dipstick - Sample
Oil dipstick
The oil-level is to be checked by means of the oil dipstick.
The prescribed filling level must not cross the „Max“-mark.
We recommend an oil-level of 2/3.
Sample picture
2/3 Suggestion
Oil Max.