![Firstmark Controls 160001-01 Installation Manual Download Page 9](http://html1.mh-extra.com/html/firstmark-controls/160001-01/160001-01_installation-manual_2294059009.webp)
Installation Guide - Position Transducers
How do I adjust the zero and span for the voltage conditioner, 4-20 mA, and bridge output signal conditioners?
First, unscrew the sealing screws labeled "Z" and "S" on the position transducer. Then, using a small, flat-
tipped screwdriver, rotate the appropriate trim potentiometer to adjust the zero and/or span. Clockwise rotation
increases the value and counter-clockwise rotation decreases the value.
13. Certificates of Conformance
A Certificate of Conformance is supplied with all shipments.
14. Repairs and Returns
Firstmark Controls position transducers are rugged and built to last. Nevertheless, adverse environments
and extraordinary use may require the products to be repaired. If your position transducer requires repair, service,
or return, submit an RMA (return material authorization) request at
. Return the product per the
instructions in the Web RMA form.
15. Warranty
See Policies and Conditions at
16. General Disclaimer
See Policies and Conditions at
17. Limitations on the Use of Products
See Policies and Conditions at
18. Record of Purchase
You may want to record information about your purchase below for future reference.
●
Date of Purchase:_________________________
●
Part Number(s):_________________________
●
Serial Number(s):_________________________
●
Purchase Order:_________________________
●
Sales Order:_________________________
19. Additional Resources
These resources may be helpful in getting full use of your position transducer:
●
●
Frequently Asked Questions (FAQs)
●
String Potentiometer and String Encoder Engineering Guide
●
Application Note for Ground Vehicles/Transportation
●
Application Note for Aircraft/Aerospace
●
Application Note for Draw Wire Transducer Accuracy
●
Position Transducer Data Sheets
●
Position Measurement & Control Archives
●
Return Material Authorization Request Form
Document number: S023A(051203)