K5966-1V1 10/03 Rev. A
5HDG\*XDUG56HULHV
4XLFN6WDUW*XLGHIRU5HDG\*XDUG5DQG5HDG\*XDUG5(1
8/
ReadyGuard-R and ReadyGuard-REN are not intended for UL985 Household Fire applications unless a 24-
hour backup battery (P/N LYNXRCHKIT-HC) is installed.
Introduction
This Quick Start Guide can help you install the rechargeable ReadyGuard-R and ReadyGuard-REN quickly and easily by
providing the basic steps for installation using the built-in defaults. For more detailed information and important notes, refer to
the ReadyGuard-R Series Installation Instructions.
The following steps assume that one of the system’s default tables will be used.
For programming data values and Powerline Carrier Devices other than those listed in the default tables, see the Installation
Instructions.
Default Table Summary
Zone
Table 1
Table 2
Table 3
Table 4
1
------- ------- ------- -------
2
front door
front door
front door
front door
3
back door
back door
back door
back door
4 window garage
door
window window
5
motion detector
motion detector
window
window
6 -------
smoke
detector
window window
7
------- ------- window
window
8
------- ------- motion
detector
motion
detector
9
------- ------- smoke
detector
smoke
detector
26
loop 3 arm away
loop 3 arm away
loop 3 arm away
loop 3 arm away
27
loop 2 disarm
loop 2 disarm
loop 2 disarm
loop 2 disarm
28
loop 4 arm stay
loop 4 arm stay
loop 4 close device
loop 4 close device
29
loop 1 restore device 1
loop 1 restore device 1
loop 1 restore device 1
loop 1 restore device 1
30
loop 3 arm away
loop 3 arm away
loop 3 arm away
loop 3 arm away
31
loop 2 disarm
loop 2 disarm
loop 2 disarm
loop 2 disarm
32
loop 4 arm stay
loop 4 arm stay
loop 4 close device
loop 4 close device
33
loop 1 restore device 1
loop 1 restore device 1
loop 1 restore device 1
loop 1 restore device 1
92
duress duress duress duress
99
silent alarm
audible alarm
silent alarm
silent alarm
Master User Code
1-2-3-4
1-2-3-4
1-2-3-4
1-2-3-4
Installer
Code
4-1-1-2 4-1-1-2 4-1-1-2 4-1-1-2
Duress
Code
------ ------ ------ ------
Entering Program Mode:
Installer Code + 8 0 0
Interactive Mode
Used to Program
✻
56
Enhanced Zone Programming
Zone characteristics, report codes, and serial numbers
✻
83
Enhanced Sequential Mode
5800 Series transmitter serial numbers
✻
84
Assign Zone Voice Descriptors
Voice descriptors for each zone
Exiting Program Mode:
✻
99
allows re-entry into the Program mode using Installer Code + 8 0 0.
✻
98
inhibits re-entry into the Programming mode using the Installer Code.
NOTES:
•
Tables 2 and 4 support the automatic paging feature (open/close events reported to pager phone number),and a Powerline
Carrier Device programmed as device 8, which closes and stays closed upon burglary alarms and restores after bell timeout. For
other applications or actions (e.g., using a pulsing siren), see the
✻
80 Device Programming Menu Mode section of the
Installation Instructions.
•
Primary report format for all tables is Ademco’s Contact ID reporting. Tables 2 and 4 also use Contact ID for secondary
reporting. Tables 1, and 3 use 4+1 format for secondary reporting.
•
Table 2 records all events in the event log. Tables 1, 3, and 4 record only alarms, alarm restores, troubles, and trouble restores
in their event logs.