ReadyGuard-R and ReadyGuard-REN are not intended for UL985 Household Fire applications unless a 24-
hour backup battery  (P/N LYNXRCHKIT-HC) is installed.

 

 

Introduction 

This Quick Start Guide can help you install the rechargeable ReadyGuard-R and ReadyGuard-REN quickly and easily by 
providing the basic steps for installation using the built-in defaults.  For more detailed information and important notes, refer to 
the ReadyGuard-R Series Installation Instructions.  

 

The following steps assume that one of the system’s default tables will be used.  

For programming data values and Powerline Carrier Devices other than those listed in the default tables, see the Installation 
Instructions. 

 

Default Table Summary 

Zone 

Table 1 

Table 2 

Table 3 

Table 4 

------- ------- ------- ------- 

front door 

front door 

front door 

front door 

back door 

back door 

back door 

back door 

4 window  garage 

door 

window  window 

motion detector 

motion detector 

window 

window 

6 ------- 

smoke 

detector 

window  window 

------- ------- window 

window 

------- ------- motion 

detector 

motion 

detector 

------- ------- smoke 

detector 

smoke 

detector 

26 

loop 3 arm away 

loop 3 arm away 

loop 3 arm away 

loop 3 arm away 

27 

loop 2 disarm 

loop 2 disarm 

loop 2 disarm 

loop 2 disarm 

28 

loop 4 arm stay 

loop 4 arm stay 

loop 4 close device 

loop 4 close device 

29 

loop 1 restore device 1 

loop 1 restore device 1 

loop 1 restore device 1 

loop 1 restore device 1 

30 

loop 3 arm away 

loop 3 arm away 

loop 3 arm away 

loop 3 arm away 

31 

loop 2 disarm 

loop 2 disarm 

loop 2 disarm 

loop 2 disarm 

32 

loop 4 arm stay 

loop 4 arm stay 

loop 4 close device 

loop 4 close device 

33 

loop 1 restore device 1 

loop 1 restore device 1 

loop 1 restore device 1 

loop 1 restore device 1 

92 

duress duress duress duress 

99 

silent alarm 

audible alarm 

silent alarm 

silent alarm 

Master User Code 

1-2-3-4 

1-2-3-4 

1-2-3-4 

1-2-3-4 

Installer 

Code 

4-1-1-2 4-1-1-2 4-1-1-2 4-1-1-2 

Duress 

Code 

------ ------ ------ ------ 

 

Entering Program Mode: 

Installer Code + 8 0 0

 

 

Interactive Mode 

Used to Program 

56

 Enhanced Zone Programming 

Zone characteristics, report codes, and serial numbers 

83

 Enhanced Sequential Mode 

5800 Series transmitter serial numbers 

84

 Assign Zone Voice Descriptors 

Voice descriptors for each zone 

 

Exiting Program Mode:

 

99

 allows re-entry into the Program mode using Installer Code + 8  0  0.

 

 

98 

inhibits re-entry into the Programming mode using the Installer Code.  

 

NOTES: 

  Tables 2 and 4 support the automatic paging feature (open/close events reported to pager phone number),and a Powerline 

Carrier Device programmed as device 8, which closes and stays closed upon burglary alarms and restores after bell timeout. For 
other applications or actions (e.g., using a pulsing siren), see the 

80 Device Programming Menu Mode section of the 

Installation Instructions. 

  Primary report format for all tables is Ademco’s Contact ID reporting. Tables 2 and 4 also use Contact ID for secondary 

reporting. Tables 1, and 3 use 4+1 format for secondary reporting. 

  Table 2 records all events in the event log. Tables 1, 3, and 4 record only alarms, alarm restores, troubles, and trouble restores 

in their event logs. 

 

Summary of Contents for ReadyGuard-REN

Page 1: ...p 3 arm away loop 3 arm away loop 3 arm away 31 loop 2 disarm loop 2 disarm loop 2 disarm loop 2 disarm 32 loop 4 arm stay loop 4 arm stay loop 4 close device loop 4 close device 33 loop 1 restore dev...

Page 2: ...and 14 respectively Note Install Powerline Carrier Devices according to their instructions f Connect wires from the 1332 1332X10 1332CN AC Transformer to terminals 15 and 16 3 Make battery connection...

Page 3: ...or to the system programming Step Action 1 Set a programming default as follows a Enter Programming mode Installer Code 8 0 0 b Press 97 then press a number 1 4 to select a default table from the tabl...

Page 4: ...entered the keypad will beep three times and C will be displayed This indicates that the serial number transmission has been confirmed to match No further transmissions will be received Note When con...

Page 5: ...installation and programming enter Installer Code TEST b To exit Test mode enter Installer Code OFF 7 Assign desired User Codes by following the procedures on the next page and in the User Guide Show...

Page 6: ...message playback system announcement volume FUNCTION VOLUME 3 Up or 6 Down To mute system announcements FUNCTION VOLUME OFF To restore unmute announcements volume FUNCTION VOLUME 3 or 6 Note If the s...

Page 7: ...r Phone Operation ReadyGuard REN Only Note The ARMED and READY LEDs blink alternately when the Speaker Phone feature is active To place a call or answer a call using the speaker phone AUX To Flash swi...

Page 8: ...165 Eileen Way Syosset New York 11791 http www firstalertpro com Copyright 2003 Honeywell International Inc i 9 l K5966 1V1 10 03 Rev A...

Reviews: